Where flammable gas may leak, where there is carbon fi
-
ber, or ignitable dust suspension in the air, or where vola-
tile flammables such as thinner or gasoline are handled.
Operating the unit in such conditions may result in a fire.
note:
Cannot be installed suspended from ceiling or stacked.
cAUtion
W
hen
operatIng
the
aIr
condItIoner
In
a
loW
outdoor
amBIent
temperature
,
Be
Sure
to
folloW
the
InStructIonS
deScrIBed
BeloW
.
•
t
o
prevent
expoSure
to
WInd
,
InStall
the
outdoor
unIt
WIth
ItS
SuctIon
SIde
facIng
the
Wall
.
•
n
ever
InStall
the
outdoor
unIt
at
a
SIte
Where
the
SuctIon
SIde
may
Be
expoSed
dIrectly
to
WInd
.
•
t
o
prevent
expoSure
to
WInd
,
It
IS
recommended
to
InStall
a
Baffle
plate
on
the
aIr
dIScharge
SIde
of
the
outdoor
unIt
.
•
I
n
heavy
SnoWfall
areaS
,
Select
an
InStallatIon
SIte
Where
the
SnoW
WIll
not
affect
the
unIt
.
• Construct a large
canopy.
• Construct a pedestal.
Install the unit high
enough off the ground
to prevent burying in
snow.
p
recautIonS
for
I
nStallatIon
•
Check the strength and level of the installation ground
so that the unit will not cause any operating vibration or
noise after installed.
• Fix the unit securely by means of the foundation bolts.
(Prepare 4 sets of 1/2” foundation bolts, nuts and wash-
ers; all separately available.)
•
It is best to screw in the foundation bolts until their ends
are 1 inch from the foundation surface.
1”
I
nStallatIon
c
learanceS
•
Where a wall or other obstacle is in the path of the out-
door unit’s intake or exhaust airflow, follow the installation
space requirements below.
•
For any of the below installation patterns, the wall height
on the outlet side should be 47” or less.
Wall facing one side
More than 4”
More than 20”
Direction
of air
47” or
less
Side view
Walls facing two sides
More than 4”
More than 4”
More
than 20”
More
than 4”
More
than 4”
More
than 20”
Top view
More
than 40”
More than 8”
More than 12”
More than 12”
More than 40”
More than 4”
More than 4”
Top view
Walls facing three sides
More than 4”
More than 4”
More than 20”
Top view
unit: inch
This unit can be located at ground floor level or on flat roofs.
At ground floor level, the unit must be on a solid, level foun
-
dation that will not shift or settle. To reduce the possibility
of sound transmission, the foundation slab should not be in
contact with or be an integral part of the building foundation.
Care should be taken to ensure the unit is installed away
from noise sensitive locations such as bedrooms, windows
and outdoor living areas. Ensure the foundation is sufficient
to support the unit. A concrete slab raised above ground level
provides a suitable base.
r
ooftop
I
nStallatIonS
If it is necessary to install this unit on a roof structure, ensure
the roof structure can support the weight and that proper
consideration is given to the weather-tight integrity of the roof.
Since the unit can vibrate during operation, sound vibration
transmission should be considered when installing the unit.
Vibration absorbing pads or springs can be installed between
the air conditioner unit legs or frame and the roof mounting
assembly to reduce noise vibration.