10
•
n
ever
InStall
a
phaSe
-
advancIng
capacItor
. a
S
thIS
unIt
IS
equIpped
WIth
an
Inverter
,
InStallIng
a
phaSe
-
advancIng
capacI
-
tor
WIll
not
only
deterIorate
poWer
factor
Improvement
ef
-
fect
,
But
alSo
may
cauSe
capacItor
aBnormal
heatIng
accIdent
due
to
hIgh
-
frequency
WaveS
.
•
d
o
not
change
the
SettIng
of
the
protectIon
devIceS
. I
f
the
preSSure
SWItch
,
thermal
SWItch
,
or
other
protectIon
devIce
IS
Shorted
and
operated
forcIBly
,
or
partS
other
than
thoSe
SpecIfIed
By
d
aIkIn
are
uSed
,
fIre
or
exploSIon
could
reSult
.
•
d
o
not
connect
the
ground
WIre
to
SuctIon
lIne
,
SeWage
pIpeS
,
lIghtnIng
rodS
,
or
telephone
ground
WIreS
.
notice
The air conditioner rating plate lists pertinent electrical data
necessary for proper electrical service and overcurrent protec-
tion. Wires should be sized to limit voltage drop to 2% (max.)
from the main breaker or fuse panel to the air conditioner.
Consult the NEC, CEC, and all local codes to determine the
correct wire gauge and length.
Local codes often require a disconnect switch located near
the unit; do not install the switch on the unit.
o
vercurrent
p
rotectIon
The inverter control system software provides sufficient time
delay to protect from overcurrent conditions and permit the
compressor and fan motors to adjust their rotational speed.
h
Igh
v
oltage
c
onnectIonS
Route power supply and ground wires through the high volt-
age port and terminate in accordance with the wiring diagram.
cAUtion
•
B
efore
connectIng
the
WIrIng
to
the
termInal
Block
,
remove
the
ShIeldIng
plate
. a
nd
take
It
Back
after
WorkIng
.
•
p
recautIonS
to
Be
taken
for
poWer
Supply
WIrIng
.
W
hen
uSIng
Stranded
WIreS
,
make
Sure
to
uSe
a
round
crImp
-
Style
termInal
for
connectIon
to
the
poWer
Supply
termInal
Block
.
p
lace
the
round
crImp
-
Style
termInalS
on
the
WIreS
up
to
the
covered
part
and
Secure
In
place
.
Round crimp-style
terminal
Stranded wire
Cup washer
Good
Cup washer
Cup washer
Screw
Screw
Screw
Round
crimp-style
terminal
Round crimp-
style terminal
Round crimp-
style terminal
A
Wrong
Arrow view
A
Notch side
•
W
hen
connectIng
the
connectIon
WIreS
to
the
termInal
Block
uSIng
a
SIngle
core
WIre
,
Be
Sure
to
curl
the
end
of
the
lead
.
I
mproper
Work
may
cauSe
heat
and
fIreS
.
Good
Wrong
Good
Wrong
Excessive strip length
may cause electric shock
or current leakage.
Strip wire end
to this point.
•
u
Se
the
folloWIng
method
When
InStallIng
a
SIngle
core
WIre
.
Cup
washer
Screw
A single core wire
A single core wire
B
Arrow view
B
•
Make sure to apply the rated voltage of 208/230V for the
unit.
•
A power circuit (see the following table) must be provided
for connection of the unit. This circuit must be protected
with the required safety devices.
•
When using residual current operated circuit breakers, be
sure to use a high-speed type (0.1 seconds or less) 200
mA rated residual operating current.
•
Use copper conductors only.
•
Use insulated wire for the power cord.
•
Select the power supply cable type and size in accor-
dance with relevant local and national regulations.