The condenser unit is shipped with a predetermined factory charge level as shown below. For longer line sets greater than
15 ft. (Detail shown in tables on page 12) add 0.6 ounce of refrigerant per foot. Refer to the following page for the equivalent
length of the elbow fittings.
total refriger-
ant (A)
=
factory charge
(B)
+
Additional charge (c)
= [for liquid line (c)-1] – [Adjust amount from suction line (c)-2]
(A) to (C) parameters are calculated/followed below.
(A) There is 2 way calculation for total refrigerant amount
(A)-1
Select line set length from (A)-1 table.
(A)-2
Calculate from above formula by using (B), (C)-1 and (C)-2 factors.
(B) Pick up from name plate which has factory charge amount.
(C) Calculate above formula. (C)-1 and (C)-2 shown below.
Subtract factory charge length (see (A)-1 Table) from the overall length and put the results in
ft.
Additional Charge for
liquid line (C)-1
=
(3/8” liquid line)
ft. x 0.6 oz.
Adjust amount from
suction line (C)-2
=
Check the suction line diameter and
pick the adjust amount (oz.)
charge table for total/Additional refrigerant (A)-1
Actual Line Set Length (ft.)
3.5/4.0 Ton
5.0 Ton
Total refrigerant (oz.)
Liquid Line Diameter (inch)
3/8”
Suction Line Diameter (inch)
1 1/8”
Total/Additional
Total
Additional
Total
Additional
15
116
0
139
0
20
119
3
142
3
25
122
6
145
6
30
125
9
148
9
35
128
12
151
12
40
131
15
154
15
45
134
18
157
18
50
137
21
160
21
55
140
24
163
24
60
143
27
166
27
65
146
30
169
30
70
149
33
172
33
75
152
36
175
36
80
155
39
178
39
85
158
42
181
42
90
161
45
184
45
95
164
48
187
48
100
167
51
190
51
Factory Charge