HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
41
DSG060*1D SINGLE PHASE 208/230V/60HZ
DIRECT DRIVE
AUXILIARY LIMIT SWITCH
FEMALE PLUG/CONNECTOR
INTEGRATED IGNITION CONTROL
VMR
LS
4
INSTALLER/SERVICEMAN
STATU
3 BLINKS
6 BLINKS
2 BLINKS
4 BLINKS
5 BLINKS
OFF
ON
1 BLINK
OPEN AUX. LIMIT
FALSE
FLAME
OUTPUT DELAY
OPEN LIMIT SWITCH
COMPRESSOR
WITHOUT
PRESSURE SWITCH
SWITCH
OPEN
OPEN ROLLOUT
SWITCH
IGNITION FAILURE
NORMAL
NO POWER OR
INTERNAL CONTROL
EQUIP. STATUS
OR
OR
FAULT
G
R
5
7
9
Y2
Y1
3
6
12
10
8
11
RS
ALS
PS
BAD SWITCH
AUX
MAIN LIMIT OPEN
BAD SWITCH
3
PR
PR
CHECK
CHECK
GAS PRESSURE
FLAME
FLAME
SENSOR
GAS
VALVE
GAS
FLOW
CHECK
-
C
4
3 2 1
5
GV
IGN
NOTE
6
L1
F
H
C
D1
FS
R
CM
CONDENSER MOTOR
N
C
EM
FS
II
L2
LS
LIMIT SWITCH
VENT
VENT MOTOR
PRESSURE SWITCH
TERMINAL BLOCK (24V SIGNAL)
ROLL OUT SWITCH
VMR
VM
PS
PLF
TB1
RS
CONTACTOR
GAS VALVE
IGNI
EQUIPMENT GROUND
FLAME SENSOR
EVAPORA
RCCF
FUSE
F
C
GV
FS
GND
IGN
II
EM
COMPRESSOR
COMP
ALS
TB1
TB1
TB1
T
TR
TRANSFORMER
C
L2
L2
VM
R
SUPPLY VOLTAGE
240/1/60
L1
2
1
3
T1
EM
L
N
C
R
S
H
C
CM
VM
C
LPS
HPS
H
HPS
LOW PRESSURE SWITCH
LPS
COOLING SPEED (YELLOW WIRE)
3. FOR DIFFERENT THAN FACTORY SPEED TAP.
CHANGE COOLING SPEED AT MOTOR T4 AND
T5 TERMINALS. CHANGE HEATING SPEED AT
MOTOR T1. T2, AND T3 TERMINALS
4. ACCESSORY ECONOMIZER PLUG ADJACENT
TO BLOWER HOUSING IN RETURN AIR
COMPARTMENT. REMOVE MALE PLUG AND
ATTACH FEMALE PLUG TO ECONOMIZER
ACCESSORY.
1. REPLACEMENT WIRE MUST BE THE SAME
SIZE AND TYPE OF INSULATION AS ORIGINAL.
(USE COPPER CONDUCTOR ONLY).
T3 - LOW SPEED
T4 - HIGH SPEED
NOTES
FACTORY WIRING
LOW VOLTAGE
BL
RD
YL
W
BL
G
R
W
NO ECONOMIZER
G
RD
PK
WH
W
R
RD
WH
GR
C
R
YL
GR
G
WH
C
GR
BL
C
2 STAGE COOLING
T 1
B
G
R
W
C
T 1
B
T 1
B
Y
W
R
G
C
W
Y2
G
R
C
STAT
STAT
STAT
BL/PK BLUE WITH PINK STIP
YL/PK YELLOW WITH PINK STRIP
GR GREEN
WIRE CODE
BL
BLUE
PU PURPLE
WH
WHITE
BK
B
BLACK
BR BROWN
OR ORANGE
YL
YELLOW
6. L1 AND L2 ON ICC CONTROLS IS 24V INPUT.
7. SPEED TAP TERMINATIONS SHOWN ON
DIAGRAM ARE REPRESENTATIVE, BUT
ACTUAL FACTORY SETTINGS MAY BE
DIFFERENT BASED ON THE HEATING VALUE
OF THE UNIT.
8 . FOR LOW STAGE OPERATION ONLY, REMOVE
WHITE JUMPER. FOR 2 STAGE OPERATION,
REMOVE JUMPER AND CONNECT W2 TO W2
ON THERMOSTAT.
3
1
AUXILIARY LIMIT SWITCH
FEMALE PLUG/CONNECTOR
INTEGRATED IGNITION CONTROL
VMR
LS
4
INS
STATUS LIGHT
3 BLINKS
6 BLINKS
2 BLINKS
4 BLINKS
5 BLINKS
OFF
ON
1 BLINK
FALSE
FLAME SENSED
OUTPUT DELAY
COMPR
WITHOUT INDUCER
SWITCH
SWITCH
IGNITION FAIL
NORMAL OPERATION
NO POWER OR
INTE
OR
OR
FAULT
TO THERMOSTAT
TERMINAL BLOCK
G
R
5
7
9
ECON
IIC
W1
Y1
3
6
12
10
8
11
RS
ALS
PS
AUX. LIMIT OPEN
3 MIN. COMP
PRESSURE SWITCH
PRESSURE SWITCH
FLAME ROLLOUT
FLAME
SENSOR
GAS
GAS
FLOW
-
PLF
C
NOTE 4
4
3 2 1
5
6
GV
IGN
NOTE
6
L1
F
H
C
D1
FS
R
CM
CONDENSER MO
NOTE 6
C
EM
FS
IIC
L2
LS
LIMIT SWITCH
VENT MOTOR RELAY
VENT M
PRESSURE SWITCH
TERMINAL BLOCK
VMR
VM
PS
PLF
TB1
RS
RUN CAPACITOR FOR COMPRESSOR/FAN
CONTACTOR
GAS VALVE
IGNITOR
EQUIPMENT GROUND
FLAME SENSOR
EVAPORATOR MOTOR
RCCF
FUSE
F
C
GV
FS
GND
IGN
IIC
EM
COMPRESSOR
COMPONENT LEGEND
COMP
ALS
TB1
TB1
TB1
T
TRANSFORMER
C
L2
L2
VM
R
L1
2
1
3
T1
EM
L
N
C
R
S
H
C
CM
F
VM
C
LPS
HPS
HIGH PRESSURE SWITCH
HPS
LOW PRES
LPS
++
USE NEC CLASS 2 WIRE.
5. USE COPPER CONDUCTORS ONLY.
T3 - LOW SPEED
T4 - HIGH SPEED
HEATING SPEED (WHITE WIRE)
T5 - HIGH SPEED (140)
T2 - MED. SPEED
T1 - LOW SPEED (070)
HIGH VOLTAGE
OPTIONAL HIGH VOLTAGE
OPTIONAL LOW VOLTAGE
FIELD WIRING
LINE VOLTAGE
LOW VOLTAGE
L
RD
Y1
YL
W
BL
G
R
W
G
YL
RD
Y1
PK
WH
W
R
RD
WH
GR
C
R
YL
GR
Y1
G
WH
WITH ECONOMIZER OPTION
C
GR
THERMOSTAT
FIELD WIRING
BL
C
G
R
W
Y
C
Y
W
R
G
C
W
Y2
G
R
C
Y1
STAT
STAT
STAT
PK
P
PINK
RD
RED
SEE UNIT RATING PLATE FOR TYPE AND SIZE
OF OVER CURRENT PROTECTION .
W2
3
1
2. FOR 208
VOLT TRANSFORMER OPERATION
MOVE BLACK WIRE FROM TERMINAL 3 TO
TERMINAL 2 ON TRANSFORMER.
7
8
9
S1 S2
Y2
Y2
Y2
240/1/60
0140L02912-C
EQUIPMENT
GROUND
FIELD GROUND
FIELD SPLICE
SWITCH (TEMP)
IGNITER
SWITCH (PRESS
.
)
OVERCURRENT
PROT. DEVICE
JUNCTION
TERMINAL
INTERNAL TO
INTEGRATED
CONTROL
PLUG
CONNECTION
++
++
6