6 Operation

Installer and user reference guide

8

BRK+S

Wired remote controller

4P513689-1A – 2018.03

3

Press 

 to confirm.

Result: 

The  indoor  unit  changes  its  airflow  direction  and  the

controller returns to the home screen.

6.4.2

Fan speed

The fan speed is the strength of the airflow coming out of the indoor
unit.

About fan speed

Depending on the indoor unit, you can choose between either:

Fan speed

Screen

2 fan speeds

3 fan speeds

5 fan speeds

Some  indoor  units  additionally  support  Automatic  fan  speed.  In  this
case,  the  indoor  unit  adjusts  its  fan  speed  automatically,  according
to the setpoint and indoor temperature.

Fan speed

Screen

Automatic

INFORMATION

▪ For  mechanical  protection  purposes,  it  is  possible  that

the  indoor  unit  switches  itself  to  'Automatic  fan  speed'
mode.

▪ If  the  fan  stops  operating,  this  does  not  necessarily

mean system failure. The fan can stop operating at all
times.

▪ It  may  take  some  time  before  changes  made  to  fan

speed settings are actually carried out.

To set the fan speed

1

Navigate to the fan speed menu.

2

Use 

 and 

 to adjust the fan speed.

3

Press 

 to confirm.

Result: 

The  indoor  unit  changes  its  fan  speed  and  the  controller

returns to the home screen.

6.5

Ventilation

INFORMATION

Ventilation  settings  can  ONLY  be  made  for  heat  reclaim
ventilation units.

6.5.1

Ventilation mode

The  heat  reclaim  ventilation  unit  can  operate  in  various  operation
modes.

Icon

Ventilation mode

Energy Reclaim Ventilation. 

The outdoor air is

supplied to the room after passing through a heat
exchanger.

Bypass. 

The outdoor air is supplied to the room

without passing through a heat exchanger.

Auto. 

To ventilate the room in the most efficient way,

the heat reclaim ventilation unit automatically
switches between "Bypass" and "Energy Reclaim
Ventilation" mode (based on internal calculations).

INFORMATION

Depending  on  the  heat  reclaim  ventilation  unit,  more  or
less ventilation modes are available.

NOTICE

Before starting up the system, the unit MUST be energised
for at least 6 hours to avoid compressor breakdown during
startup.

INFORMATION

To ensure a smooth start, do not turn off the system while
it is operating.

To set the ventilation mode

1

Navigate to the ventilation mode menu.

2

Use 

 and 

 to select a ventilation mode.

3

Press 

 to activate.

Result: 

The heat reclaim ventilation unit changes its operation mode

and the controller returns to the home screen.

Summary of Contents for BRC1H519K

Page 1: ...Installer and user reference guide Wired remote controller English Installer and user reference guide Wired remote controller BRC1H519W BRC1H519K BRC1H519S...

Page 2: ...m 12 12 1 Master and slave controller 12 12 2 To designate a controller as slave 12 13 Operation 13 13 1 Buttons 13 13 2 Screen 13 13 3 Status indicator 13 13 4 Information 13 13 4 1 Information scree...

Page 3: ...ay or insecticide near the controller NOTICE To clean the controller do NOT use organic solvents such as paint thinner Possible consequence damage electric shock or fire 1 2 For the installer The prec...

Page 4: ...ngineering data A subset of the latest technical data is available on the regional Daikin website publicly accessible The full set of latest technical data is available on the Daikin extranet authenti...

Page 5: ...ation Indicates that Rotation mode is active Setback Indicates that the indoor unit is operating under setback conditions Icon Description Ventilation Indicates that a heat reclaim ventilation unit is...

Page 6: ...t the system will automatically switch to defrost operation During defrost operation the indoor unit fan will stop operation and the following icon will appear on the home screen The system will resum...

Page 7: ...ycle through the menu until all fields are set correctly Result You set the date and the time INFORMATION Confirming the value in a field will automatically bring you to the next field To finish makin...

Page 8: ...s to confirm Result The indoor unit changes its fan speed and the controller returns to the home screen 6 5 Ventilation INFORMATION Ventilation settings can ONLY be made for heat reclaim ventilation u...

Page 9: ...ructions from there 7 Maintenance and service 7 1 Overview Maintenance and service When the system needs to be maintained or serviced consult your dealer When the following indoor unit components are...

Page 10: ...he controller 11 2 1 About mounting the controller Before you can mount the controller you have to determine the wiring routing and accordingly remove a piece of the controller s rear casing The wirin...

Page 11: ...1 Precautions when closing the controller CAUTION Never touch the internal parts of the controller CAUTION When closing the controller be careful not to pinch the wiring NOTICE To prevent damage make...

Page 12: ...1 Information screen on page 13 INFORMATION It is only possible to use a master and a slave controller of the same type INFORMATION In case digital input adapter BRP7A5 is part of the system it is not...

Page 13: ...ssages b Active operation mode c Setpoint temperature Home screen mode is set with remote controller field setting R1 7 Home screen For more information see Remote controller field settings on page 19...

Page 14: ...r instructions on how to enter the information menu see 14 1 Installer menu on page 14 and Information on page 27 14 Configuration 14 1 Installer menu 14 1 1 About the installer menu In the installer...

Page 15: ...ions on how to make field settings see 14 1 4 Field settings on page 15 For an overview of remote controller field settings see Remote controller field settings on page 19 To set status indicator inte...

Page 16: ...s you do NOT set the unit number The settings will then apply to all indoor units that are part of that group Second level Setting SW A setting is a settable parameter These are the settings you are m...

Page 17: ...ing component 3 Use and to change the value of that field setting component 4 Press to confirm that value 5 In the first level select to move to the second level 6 In the second level navigate and sel...

Page 18: ...sor set the increase decrease increments 1 C 0 5 C 13 23 00 High air outlet velocity set in case of high ceiling applications h 2 7 m 2 7 m h 3 m 3 m h 3 5 m 01 Airflow direction set in case an indoor...

Page 19: ...C 10 2 0 C 11 2 5 C 12 3 0 C 6 7 Home screen 0 Detailed 1 Standard 1 8 Backlight no operation timer 0 5 seconds 1 10 seconds 2 20 seconds 0 9 Status indicator faintness 0 0 OFF 1 1 2 2 3 3 4 5 5 7 6...

Page 20: ...ellaneous settings Group address and Airnet address DIII Group address To control the system with central control equipment you need to set addresses for Groups Group and or Units Group Unit The Group...

Page 21: ...settings To RELEASE an address that was previously set change to and then apply settings AirNet address To connect the system to the AirNet monitoring and diagnostics system you need to set AirNet ad...

Page 22: ...controller 4P513689 1A 2018 03 Address Description First level Indoor unit I U Define the indoor unit for which you want to set an AirNet address Proceed to the next level Outdoor unit O U Define the...

Page 23: ...gital input adapter see the installation manual of the digital input adapter In case the digital input adapter does not function properly the external input interlock menu is not available in the inst...

Page 24: ...setpoint range and setpoint range limitation 22 C Reset Heat SP Default Reset Setting heating setpoint See indoor unit s setpoint range and setpoint range limitation 22 C INFORMATION When the value f...

Page 25: ...the previous state When the key card contact is opened while the window contact is open the delay timer will start running When the delay timer expires the reset timer will start running When the res...

Page 26: ...Cooling Heating masterhood on page 26 Cooling Heating masterhood corresponds to the following status icon The behaviour of this status icon is according to the following table If a controller display...

Page 27: ...g masterhood menu 2 Press to release the indoor unit from its masterhood Result The indoor unit is released from its masterhood Result The controllers of all indoor units display a blinking changeover...

Page 28: ...Prerequisite You are close to the controller 1 In the app tap the controller that you want to pair with Result The operating system of your mobile device sends out a pairing request Result The contro...

Page 29: ...hange the operation mode Change the setpoint Change the fan speed Change the airflow direction Read out notifications Category Control Configuration and advanced operation Make controller and indoor u...

Page 30: ...date and time menu you send date and time information to the remote controller from the app You can choose to either send the date and time information of your mobile device Synchronise or to manually...

Page 31: ...ORMATION The availability of this function depends on the type of indoor unit 15 5 13 Setpoint range Set a limitation to the temperature setpoint range of both Cooling and Heating operation INFORMATIO...

Page 32: ...n it is required that the indoor units are equipped with a self cleaning decoration panel optional accessory 15 5 20 AirNet address Assign AirNet addresses to the indoor and outdoor units this to conn...

Page 33: ...units can remain inactive during normal operation After a set time i e Rotation cycle time the inactive unit will start operation and a previously active unit will become inactive i e duty rotation Be...

Page 34: ...behave correspondingly 12 Return to the Test operation menu 13 Tap Stop test operation Result The indoor units leave test operation mode Normal operation is possible again 14 Go to 6 Operation on page...

Page 35: ...Wipe the screen and other surface parts of the controller with a dry cloth 17 Troubleshooting 17 1 Error codes of the indoor unit When the indoor unit is in error the controller will display on the ho...

Page 36: ...is available on the regional Daikin website publicly accessible The full set of latest technical data is available on the Daikin extranet authentication required 18 1 Connection diagram 18 1 1 Typica...

Page 37: ...ference guide 37 BRC1H519W K S Wired remote controller 4P513689 1A 2018 03 Group control controller digital inputs adapter BRP7A5 0 1 2 P1 P2 P1 P2 P1 P2 P1 P2 P1 P2 18 1 3 Controller DIII central con...

Page 38: ......

Page 39: ......

Page 40: ...4P513689 1A 2018 03 Copyright 2018 Daikin...

Reviews: