![Daikin ARXN25MV1B Service Manual Download Page 20](http://html.mh-extra.com/html/daikin/arxn25mv1b/arxn25mv1b_service-manual_501334020.webp)
Function & Control
14
2.2.2 Heating Mode:
When Ts > Tr - 1.0°C
• Compressor, Indoor Fan and Outdoor Fan ON.
When
Ts
≤
Tr - 1.5°C
• Compressor and Outdoor Fan OFF. Indoor Fan remained ON.
• Indoor Fan off if indoor coil
≤
20°C.
Tr = Room Temperature
Ts = Set Temperature
When heating load is too small, and the room temperature still rising above compressor cut off point,
compressor will stop.
Compressor Capacity
Lowest Frequency
Time
Tr - T
V&
Compressor will stop
2.3 Fan Mode
• Compressor and Outdoor Fan OFF. Indoor Fan remained ON.
• Only High, Medium and Low fan speeds are allowed.
• When changing cool mode to fan mode, the compressor will stop and OD fan stops based on fan OFF
control.
• Compressor only ON if the minimum stop time is > 3 minutes and the user change back to cool mode.
• Fan speed will maintain same as during fan mode.
2.4 Auto Mode
Automatic Cooling / Heating Function
When the automatic operation is selected with the remote controller, the microcomputer automatically
determines the operation mode as cooling or heating according to the room temperature and the set
temperature at start-up.
The unit automatically switches the operation mode to maintain the room temperature at the set temperature.
For heat pump only
Mode switching point:
• From Heating
to
Cooling
Tr
≥
Ts + 2.5
• From Cooling
to
Heating
Tr
≤
Ts – 2.5
During initial operation
• Cooling operation: Tr > Ts
• Heating operation: Tr < Ts
2.5 Cold Draft Prevention
During each thermal cut in cycle, the indoor fan speed will modulate according to the indoor coil temperature.
•
If indoor coil temperature > 36
°
C, indoor fan will run at user set fan speed.
•
If indoor coil temperature < 15
°
C, indoor fan will stop.
•
If indoor coil temperature 15
°
C<X < 36
°
C, the indoor fan will run at low speed
Summary of Contents for ARXN25MV1B
Page 1: ...SERVICE MANUAL Inverter DOO 0RXQWHG Single Split SM 5WMY A1 R410A ...
Page 60: ...Wiring Connection 54 4 0 Wiring Connection Model ATXN FTXN 25 35L M ARXN RXN 25 35L M ...
Page 61: ...Wiring Connection 55 Model ATXN FTXN 50 60L ARXN RXN 50 60L ...
Page 62: ...Wiring Connection 56 Model ATXN FTXN 50 60M ARXN RXN 50 60M ...