![Daikin ARXN25MV1B Service Manual Download Page 15](http://html.mh-extra.com/html/daikin/arxn25mv1b/arxn25mv1b_service-manual_501334015.webp)
Inverter Single Split
9
1.2.4.2 Main PCB
Item Indication on PCB
Description
1
S10
Connector for S11 on fi lter PCB
2
S12
Connector for HL4 HN4 on fi lter PCB
3
S20
Connector for electronic expansion valve coil
4
S40
Connector for overload protector
5
S50
Connector for magnetic relay
6
S70
Connector for fan motor
7
S80
Connector for four way valve coil
8
S90
Connector for thermistors (outdoor temperature, outdoor
heat exchanger, discharge pipe)
9
HL3, HN3
Connector for HL2 HN2 on fi lter PCB
10
U, V, W
Terminal for compressor
11
FU2
Fuse (3.15A, 250V)
12
LED A
LED for service monitor (green)
13
V1
Varistor