![background image](http://html.mh-extra.com/html/daikin/altherma-edlq011-016aa6v3/altherma-edlq011-016aa6v3_technical-data-manual_501255011.webp)
• Altherma
TM
• Outdoor units
11
• Outdoor units • ERHQ006-008AD
2
Specifications
1
2
2-1 NOMINAL CAPACITY AND
NOMINAL INPUT
ERHQ006AD
ERHQ007AD
ERHQ008AD
For
combination
indoor units +
outdoor units
Indoor Units
EKHBH008AA
Condition 1
Heating
capacity
Minimum kW
4.36
4.36
4.36
Nominal
kW
5.75
6.84
8.43
Maximum kW
7.45
8.79
9.58
Heating PI
Nominal
kW
1.26
1.58
2.08
COP
Nominal
4.56
4.34
4.05
Nominal
Capacity
Heating
capacity
Minimum kW
3.87
3.87
3.87
Nominal
kW
5.03
6.10
7.64
Maximum kW
6.68
7.98
8.76
Heating PI
Nominal
kW
1.58
1.95
2.54
COP
Nominal
3.18
3.13
3.00
For
combination
indoor units +
outdoor units
Indoor Units
EKHBX008AA
Condition 1
Heating
capacity
Minimum kW
4.36
4.36
4.36
Nominal
kW
5.75
6.84
8.43
Maximum kW
7.45
8.79
9.58
Cooling
capacity
Minimum kW
4.82
4.82
4.82
Nominal
kW
7.20
8.16
8.37
Maximum kW
7.20
8.50
8.91
Heating PI
Nominal
kW
1.26
1.58
2.08
Cooling PI
Nominal
kW
2.27
2.78
2.97
COP
Nominal
4.56
4.34
4.05
EER
Nominal
3.17
2.94
2.82
Nominal
Capacity
Heating
capacity
Minimum kW
3.87
3.87
3.87
Nominal
kW
5.03
6.10
7.64
Maximum kW
6.68
7.98
8.76
Cooling
capacity
Minimum kW
3.67
3.67
3.67
Nominal
kW
5.12
5.86
6.08
Maximum kW
5.12
6.13
7.10
Heating PI
Nominal
kW
1.58
1.95
2.54
Cooling PI
Nominal
kW
2.16
2.59
2.75
COP
Nominal
3.18
3.13
3.00
EER
Nominal
2.37
2.26
2.21
Notes
Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C) - heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C ) - heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
2-2 TECHNICAL SPECIFICATIONS
ERHQ006AD
ERHQ007AD
ERHQ008AD
Casing
Colour
Ivory white
Material
Polyester painted galvanised steel
Dimensions
Unit
Height
mm
735
735
735
Width
mm
825
825
825
Depth
mm
300
300
300
Packing
Height
mm
797
797
797
Width
mm
960
960
960
Depth
mm
390
390
390
Weight
Unit
kg
56
56
56
Packed Unit
kg
61
61
61
Packing
Material
EPS
Carton
Weight
kg
5
5
5
Summary of Contents for Altherma EDLQ011-016AA6V3
Page 1: ...technical data EEDEN09 720 Altherma TM ...
Page 3: ...technical data EEDEN09 720 Altherma TM ...
Page 4: ... AlthermaTM AlthermaTM 4 A l t h e r A l t h e r R 4 1 0 A Heating only Heat pump ...
Page 6: ......
Page 7: ...technical data Part 1 4 ERHQ006 008AD EKHBH X008AA EEDEN09 720 Altherma TM ...
Page 8: ......
Page 20: ......
Page 35: ...technical data Part 2 4 ERHQ011 016AA ERHQ011 016AAW1 EKHBH X 016AB EEDEN09 720 Altherma TM ...
Page 36: ......
Page 52: ......
Page 68: ......
Page 84: ......
Page 176: ......
Page 196: ......
Page 216: ......
Page 236: ......
Page 237: ...technical data Part 4 4 EKHWS B EKHWE EKSOLHWAV1 EKRTW EKRTR EEDEN09 720 Altherma TM ...
Page 238: ......
Page 264: ......
Page 270: ......