Electric heater
Type
9WN
Power Supply
Phase
3~
Frequency
Hz
50
50
Voltage
V
400
400
Current back-up
heater
Running
Current
A
13
13
Current back-up
booster
heater (EKHWS*
models)
Running Current
*V3
A
26 (13+13)
*Z2
A
20.5 (13+7.5)
Minimum Ssc value
*V3
Equipment complying with EN/IEC 61000-3-12 **
*Z2
Equipment complying with EN/IEC 61000-3-12 **
Electric heater
Voltage range
Minimum
-10%
Maximum
+10%
Wiring connections
For power supply
backup heater
Quantity of wires
4G
Type of wires
Select diameter and type according to national and local regulations
Electric heater
Type
9T1
Power Supply
Phase
3~
Frequency
Hz
50
50
Voltage
V
230
230
Current back-up
heater
Running
Current
A
22.6
22.6
Minimum Ssc value
Equipment complying with EN/IEC 61000-3-12 **
Current back-up heater
+ booster heater
(EKHWS* models)
Running Current
*V3
A
35.6 (22.6+13)
Minimum Ssc value
*V3
Equipment complying with EN/IEC 61000-3-12 **
Electric heater
Voltage range
Minimum
-10%
Maximum
+10%
Wiring connections
For power supply
backup heater
Quantity of wires
4G
Type of wires
Select diameter and type according to national and local regulations
Connection type
For power supply connection to Optional Warm Water Tank + Q2L
Quantity of wires
3G
Type of wires
Select diameter and type according to national and local regulations
Type of wires
For more details of the voltage range and current refer to installation manual EKHBH/X016AB*
Connection type
For connection with R5T
Quantity of wires
Wire included in option EKHWS*
Type of wires
Wire included in option EKHWS*
Connection type
For connection with A3P
Quantity of wires
Depends on thermostat type, refer to installation manual EKHBH/X016AB*
Type of wires
Select diameter and type according to national and local regulations
Type of wires
Voltage: 230V/Maximum current: 100mA/Minimum 0,75 mm²
Connection type
For connection with M2S
Quantity of wires
3G
Type of wires
Select diameter and type according to national and local regulations
Type of wires
Voltage: 230V/Maximum current: 100mA/Minimum 0,75 mm²
Connection type
For connection with M3S
Quantity of wires
3G or 4G
Type of wires
Select diameter and type according to national and local regulations
Type of wires
Voltage: 230V/Maximum current: 100mA/Minimum 0,75 mm²
Notes
Above mentioned power supply of the hydro box is for the backup heater only. The Switch box &
pump of the hydrobox are supplied via the outdoor unit. The optional domestic warm water tank
has a separate power supply.
Optional electric heater has 2 capacity steps except for the 3V3 model which has only 1 capacity
step.
In accordance with EN/IEC 61000-3-11(*), it may be necessary to consult the distribution network
operator to ensure that the equipment is connected only to a supply with Zsys(***) <= Zmax
(*) European/International Technical Standard setting the limits for voltage changes, voltage
fluctuations and flicker in public low-voltage supply systems for equipment with rated current <= 75A
(**) European/International Technical Standard setting the limits for harmonic currents produced by
equipment connected to public low-voltage systems with input current >16A and <= 75A per phase
(***) System impedance
2-2 ELECTRICAL SPECIFICATIONS
EKHBH016AB
EKHBX016AB
Summary of Contents for Altherma EDLQ011-016AA6V3
Page 1: ...technical data EEDEN09 720 Altherma TM ...
Page 3: ...technical data EEDEN09 720 Altherma TM ...
Page 4: ... AlthermaTM AlthermaTM 4 A l t h e r A l t h e r R 4 1 0 A Heating only Heat pump ...
Page 6: ......
Page 7: ...technical data Part 1 4 ERHQ006 008AD EKHBH X008AA EEDEN09 720 Altherma TM ...
Page 8: ......
Page 20: ......
Page 35: ...technical data Part 2 4 ERHQ011 016AA ERHQ011 016AAW1 EKHBH X 016AB EEDEN09 720 Altherma TM ...
Page 36: ......
Page 52: ......
Page 68: ......
Page 84: ......
Page 176: ......
Page 196: ......
Page 216: ......
Page 236: ......
Page 237: ...technical data Part 4 4 EKHWS B EKHWE EKSOLHWAV1 EKRTW EKRTR EEDEN09 720 Altherma TM ...
Page 238: ......
Page 264: ......
Page 270: ......