![background image](http://html.mh-extra.com/html/daikin/altherma-edlq011-016aa6v3/altherma-edlq011-016aa6v3_technical-data-manual_501255107.webp)
• Altherma
TM
• Monobloc
107
• Monobloc • EDHQ011-016AA6W1
2
Specifications
3
2
2-4 ELECTRICAL SPECIFICATIONS
EDHQ011AA6W1
EDHQ014AA6W1
EDHQ016AA6W1
Power supply
compressor
component
Main Power
Name
W1
Phase
3N~
Frequency
Hz
50
50
50
Voltage
V
400
400
400
Voltage range
Minimum
V
-10%
Maximum
V
+10%
Current
Nominal running
current (RLA)
Heating (A)
A
5.8
5.8
5.8
Maximum running
current
Heating
A
14
14
14
Power supply
compressor
component
Current
Recomended
fuses
A
20
20
20
Wiring connections For power supply
compressor component
See installation manual
Power supply
hydraulic
component
Current back-up
heater
Type
6W1
Current back-up
heater
Power Supply
Phase
3~
Frequency
Hz
50
50
50
Voltage
V
400
400
400
Running Current
Back-up
heater
A
8.7
8.7
8.7
Running Current
Back-up
booster heater
+EK*V3
A
21.7(8.7+13)
+EK*Z2
A
16.2(8.7+7.5)
Current back-up
heater
Minimum Ssc value +EK*V3
kVa
Equipment complying with EN/IEC 61000-3-12(**)
+EK*Z2
kVa
Equipment complying with EN/IEC 61000-3-12(**)
Summary of Contents for Altherma EDLQ011-016AA6V3
Page 1: ...technical data EEDEN09 720 Altherma TM ...
Page 3: ...technical data EEDEN09 720 Altherma TM ...
Page 4: ... AlthermaTM AlthermaTM 4 A l t h e r A l t h e r R 4 1 0 A Heating only Heat pump ...
Page 6: ......
Page 7: ...technical data Part 1 4 ERHQ006 008AD EKHBH X008AA EEDEN09 720 Altherma TM ...
Page 8: ......
Page 20: ......
Page 35: ...technical data Part 2 4 ERHQ011 016AA ERHQ011 016AAW1 EKHBH X 016AB EEDEN09 720 Altherma TM ...
Page 36: ......
Page 52: ......
Page 68: ......
Page 84: ......
Page 176: ......
Page 196: ......
Page 216: ......
Page 236: ......
Page 237: ...technical data Part 4 4 EKHWS B EKHWE EKSOLHWAV1 EKRTW EKRTR EEDEN09 720 Altherma TM ...
Page 238: ......
Page 264: ......
Page 270: ......