Dimensional drawing & centre of gravity
4 - 1
Dimensional drawing
4
4
3TW57944-1
EKHWS-B
j
1
Water mains in G 3/4 (Female)
j
2
Water mains out G 3/4 (Female)
j
3
Thermistor connection
j
4
Flow (from EKHB(H/X)*) G 3/4 (Female)
j
5
Return (to EKHB(H/X)*) G 3/4 (Female)
j
6
Switchbox
j
7
Thermal protector
j
8
Anode
j
9
Cable entry: power, booster heater and thermal protection cable
j
10
Re-circulation connection: G 3/4 (Female)
j
11
Cable entry for EKSOLHWAV1: power supply from EKHB(H/X)
j
12
Cable entry for EKSOLHWAV1: power supply to EKSOLHWAV1
pump
j
13
Thermistor connection (See EKSOLHWAV1)
j
14
3 way valve
Required service space around the
tank
3 way valve
EKHWSU-B
Water connections kit
j
9
Pressure reducing valve
22MM-22MM
j
10
Expansion relief valve
22MM-22MM
j
11
T-piece (to tundish)
15MM-15MM-G 1/2 (Female)
j
12
Tundish
22MM-15MM
j
13
T-piece (to expansion vessel)
22MM-22MM-22MM
j
14
Adapter (expansion vessel)
22MM-G 3/4 (Female)
j
15
Expansion vessel
G 3/4 (Male)
j
16
Drain valve
22MM-G 2/4 (Female)
j
17
Solenoid valve
3/4’’ female BSP-3/4’’ hale BSP
Water connections
j
1
Water IN (cold)
22MM
j
2
Water OUT (hot)
G 3/4 (Female)
j
3
Flow from EKHB(H/X)*
G 3/4 (Female)
j
4
Return to EKHB(H/X)*
G 3/4 (Female)
j
5
Temperature relief valve
15MM
j
6
Thermistor connection
j
7
Thermistor connection (See EKSOLHWAV1)
G 1/2 (Female)
j
8
Re-circulation hole
G 3/4 (Combinations
compliant to NF-PAC)
Other
j
18
EKUHW2WB kit: solenoid valve (only with EKSOLHWAV1)
Rp 3/4 - Rp 3/4
j
19
Switchbox
j
20
Thermal protector 1+Thermostat
j
21
Cable entry: power supply booster heater and thermal protector cable
j
22
Cable entry for EKUHW2WB: power supply to solenoid valve
j
23
Cable entry: power supply booster heater and thermal protector cable
j
24
Blind stop + 2 plastic screw-on closing caps for pressure reducing valve
j
25
Thermal protector 2+Thermostat
j
26
Cable entry for EKSOLHWAV1: power supply to EKSOLHWAV1 pump
j
27
3 way valve
3x Rp1
Typical installation EKUHWA-kit
Required service space
3TW57944-2A
Model
H1
H2
H3
H4
EKHWSU150B3V3
900
1015
255
130
EKHWSU200B3V3
1150
1265
410
200
EKHWSU300B3V3
1600
1715
410
200
Summary of Contents for Altherma EDLQ011-016AA6V3
Page 1: ...technical data EEDEN09 720 Altherma TM ...
Page 3: ...technical data EEDEN09 720 Altherma TM ...
Page 4: ... AlthermaTM AlthermaTM 4 A l t h e r A l t h e r R 4 1 0 A Heating only Heat pump ...
Page 6: ......
Page 7: ...technical data Part 1 4 ERHQ006 008AD EKHBH X008AA EEDEN09 720 Altherma TM ...
Page 8: ......
Page 20: ......
Page 35: ...technical data Part 2 4 ERHQ011 016AA ERHQ011 016AAW1 EKHBH X 016AB EEDEN09 720 Altherma TM ...
Page 36: ......
Page 52: ......
Page 68: ......
Page 84: ......
Page 176: ......
Page 196: ......
Page 216: ......
Page 236: ......
Page 237: ...technical data Part 4 4 EKHWS B EKHWE EKSOLHWAV1 EKRTW EKRTR EEDEN09 720 Altherma TM ...
Page 238: ......
Page 264: ......
Page 270: ......