WEB Client 40
Snapshot
Configure parameters according to actual requirement. Please refer to Table 5-12 for
more details.
Table 5-12 Snapshot setting parameters description
Parameter
Note
Work Mode
Auto
Automatically select work mode according to actual scenario.
Manual
Loop: Forced to use loop for snapshot.
Video: Forced to use video for snapshot.
Mix: Forced to use coil + video mixed mode to take
snapshot.
ANPR
Parameters
Snapshot
Amount
It can take 1 to 2 snapshots.
Snapshot
Direction
Approach: Capture the entered vehicles.
Away: Capture the exited vehicles.
Double: Both entered and exited vehicles are captured.
Max pass
time
Input max vehicle passing time, the unit is s, it is 5s by default.
For example, set max vehicle passing time as 5s, when using
mix in and mix out with loop, after the logical loop is triggered, it
will trigger capture loop camera not to take snapshot within 5s.
Click
OK
to finish configuration.
5.4.1.2.2 I/O
In this section, it will configure 485 interface associated config info and loop IO snapshot config.
Select
Setting
>
ITC
>
Detection
>
I/O
, the
I/O
interface is displayed.
Start RS-485 port
Select Start RS-485 Port, but not Start Coil IO
The
Setting
interface is displayed. See Figure 5-23.