User’s Manual
59
Table 3-29 Description of serial application parameters
Parameter
Description
Baudrate
Indicates the number of bytes per second transmitted by the Router,
commonly used baud rate is 115200, 57600, 38400, 19200.
Databit
The number of data bit can be 4, 5, 6, 7, 8, and usually in ASCII code. The
transmission starts from the lowest bit and is located by the clock.
Stopbit
Indicates the end of a character data. It can be a high level of 1-bit, 1.5-bit
and 2-bit.
Parity
Indicates the data error checking method used by a set of data: Odd or
Even.
Flow Control
Includes hardware and software.
Protocol
The following protocols are available:
UDP (DTU): Serial port to UDP connection, including custom
application layer protocol, which is equivalent to the function of a IP
modem
Pure UDP: Standard serial port to UDP connection.
TCP (DTU): Serial port to TCP connection, including custom
application layer protocol, which is equivalent to the function of an IP
modem.
Pure TCP: Standard serial port to TCP connection.
TCP server: Standard TCP server connection.
TCST: Custom TCP connection.
Modbus TCP: Modbus protocol based on Ethernet TCP/IP.
DCUDP: UDP connection in CUDP mode.
DCTCP: TCP connection in CTCP mode.
Server Address
The IP address or domain name of the data service center.
Server Port
The listening port of the data service center.
Listen Port
This parameter is valid only when
Protocol
is
TCP Server
or
Modbus
TCP
.
Device Number
This parameter is valid only when
Protocol
is among
UDP(DTU)
,
TCP(DTU)
,
DCUDP
and
DCTCP
.
The ID of the Router, an 11-byte data string.
Device ID
This parameter is valid only when
Protocol
is
TCP(DTU)
or
DCTCP
.
It is an 8-byte data string.
Heartbeat Interval
This parameter is valid only when
Protocol
is among
UDP(DTU)
,
TCP(DTU)
,
TCST
,
DCUDP
and
DCTCP
.
The time interval to send heart beat packet.
Custom Heartbeat
Packet
This parameter is valid when
Protocol
is
TCST
.
Set the hearbeat packet.
Custom
Registration Packet
This parameter is valid when
Protocol
is
TCST
.
Set the registration packet.
ASCII/HEX
This parameter is valid when
Protocol
is
TCST
.
Set whether to enable ASCII/HEX.
Click
Save
to save the configuration.
Step 4
Click
Apply Settings
to apply the configuration.
Step 5
Summary of Contents for DH-WM4700-O
Page 88: ...User s Manual...