Notes
● There may be pipe vibration because Comp circulates the refrigerant with high pressure.
● When Comp vibration is transmitted to Pipe, tightly attach anti-vibration mass on the welding point or
the sharply bended point on the pipe between the pipe and Comp.
Machine-room Pipes contacted
with each other?
EVA container vibrates by Wi-
Con vibration?
Start
Separate the Pipes at the
contacted points.
N
Y
Supplement Sealing material
between Comp Base & EVA
container /
Wi-Con & bottom board.
Y
Pipe vibration severe?
N
Add anti-vibration Mass &
adjust the attachment point.
Y
Comp vibration severe?
N
Attach anti-vibration gum onto
the Comp.
N
Y
Explain to the customer in detail