1. Hissing Noise at Capi-tube
1) Connecting tube called ‘I-tube’ is used between Capi-tube and Eva, and anti-vibration gum is
attached onto the I-tube. Check if there is any bending, etc. on the tube, after removing the anti-
vibration gum.
2) The arrows in Picture ① give the welded points of the ‘I-tube’. The anti-vibration gum shall be
attached as in Picture
②
so that all the welded points may be wrapped in. (The point on the
Capi-tube shall be wrapped, with the margin of at leas 10mm beyond the point covered.)
2. Rumbling or bubbling noise from Accum
3. Eva Vibration Noise
1) The Fixture ①, ② are to fix the Eva onto the inner
board. Assemble it so that they are closely attached.
2) Insert EPS (Styrofoam) between left and right sides of Eva
and the inner board so that it may not be movable.
1
3
1
2
Actions to take for the Noise from Eva
53
2
10mm
1) Anti-vibration gum should be attached onto the
③
area of the picture above. (Existing Seal should be
removed.)
2) Separate the Accum from the inner board after the anti-vibration gum is attached.
3) Take care not to have the tubing bended, when separating them, and the Seal shall be attached onto the
previous location to maintain the distance with the inner board.
Welded Points
Summary of Contents for Q600 series
Page 7: ...3 1 Normal Compressor 3 Wiring Diagram 6...
Page 8: ...3 2 Inverter Compressor 7...
Page 9: ...4 1 FRQ 19D Dispenser only 4 External Size and Names of the Refrigerator 8...
Page 10: ...4 2 FRQ 19F Dispenser H bar 9...
Page 30: ...Contents 3 Ice Separation Mode 29...
Page 61: ...INVERTER BOX COMPRESSOR 60 INVERTER Compressor VESD11C INVERTER Compressor ENV4A5G L2B...
Page 101: ...10 4 How to install Water Line Dispenser Models only External Filter Type 100...
Page 102: ...101...