Input Parts
Control Object
Contents
1. D-Sensor
2. Initial Power Supply
1. Defrosting Mode
1. If D-Sensor ≤ 3.5℃ when the initial power supply begins, Defrosting mode will start.
2. Defrosting is made per D-Sensor.
3. When in initial Defrosting, Comp is delayed by 6min.
6-6 Initial Defrosting
Input Parts
Control Object
Contents
1.Front PCB
1. Electronic Units
1. Starting: Press “Fridge Adjustment” + “Freezing Adjustment” 10 times in the “Locked” state.
2. Control Method: Comp & F/C-Fan continuous operation. R Damper Open
3. Operation Display: “Co” displayed at Error Display Mode (Refer to Error Display)
4. Cancellation: Automatically canceled 10 hr after starting
6-7 Short Circuit Operation
Input Parts
Control Object
Contents
1.Comp
6-8. Comp RPM Control ( Inverter compressor model only )
1. Comp RPM is changed per RT-Sensor & Set operation state
Temperature Condition
~29℃
29℃ ~ 35℃
35℃ ~ 41℃
41℃ ~
Normal Operation
1800 RPM
2550 RPM
3600 RPM
3990 RPM
Load Response1
2550 RPM
3600 RPM
3990 RPM
3990 RPM
Load Response2
3990 RPM
3990 RPM
3990 RPM
3990 RPM
Quick Operation
3600 RPM
3600 RPM
3600 RPM
3990 RPM
Short Circuit Operation
3990 RPM
3990 RPM
3990 RPM
3990 RPM
2. For 5 min. after an initial power supply, 1800RPM (lowest speed) operation
N/A
22
Summary of Contents for Q600 series
Page 7: ...3 1 Normal Compressor 3 Wiring Diagram 6...
Page 8: ...3 2 Inverter Compressor 7...
Page 9: ...4 1 FRQ 19D Dispenser only 4 External Size and Names of the Refrigerator 8...
Page 10: ...4 2 FRQ 19F Dispenser H bar 9...
Page 30: ...Contents 3 Ice Separation Mode 29...
Page 61: ...INVERTER BOX COMPRESSOR 60 INVERTER Compressor VESD11C INVERTER Compressor ENV4A5G L2B...
Page 101: ...10 4 How to install Water Line Dispenser Models only External Filter Type 100...
Page 102: ...101...