Contents
4. Water-supply Mode
1)
If Water-supply mode starts after an Ice Separation, the solenoid valve will be on.
2) Water-supply is made by time: Normal supplying time 5 sec.
3) How to adjust the Water-supply time
(a) Starting of the Adjustment 1:
- (LOCKED State) Press Dispenser Button for 10 sec. to see P0 05 displayed
(b) Starting of the Adjustment 2:
- Press Freezer Dispenser Button 5 times: Error Display Mode started
- Press Freezer Button 5 times: Initially setup Water-supply time P0 05 is displayed
at 88 segment (Meaning 5 sec.)
(c) If you press Dispenser once, P0 05 is displayed (Meaning 5 sec.)
(d) Water-supply time may be up to 22 sec. -> Next to P0 22, P0 03 is set (Minimum supplying
time is 3 sec.)
(Water-supply time 3~10sec. -> Time increases by one sec. for each Dispenser pressing
Water-supply time 10~22sec. -> Time increases by two sec. for each Dispenser pressing)
Water-supply Mode Start
Water-supply solenoid Valve
ON
Water-supply Time> 5 sec.
Water-supply solenoid Valve OFF
Water-supply Mode End
30
Summary of Contents for Q600 series
Page 7: ...3 1 Normal Compressor 3 Wiring Diagram 6...
Page 8: ...3 2 Inverter Compressor 7...
Page 9: ...4 1 FRQ 19D Dispenser only 4 External Size and Names of the Refrigerator 8...
Page 10: ...4 2 FRQ 19F Dispenser H bar 9...
Page 30: ...Contents 3 Ice Separation Mode 29...
Page 61: ...INVERTER BOX COMPRESSOR 60 INVERTER Compressor VESD11C INVERTER Compressor ENV4A5G L2B...
Page 101: ...10 4 How to install Water Line Dispenser Models only External Filter Type 100...
Page 102: ...101...