![background image](http://html1.mh-extra.com/html/dab/active-ji-62/active-ji-62_instruction-for-installation-and-maintenance_3237470029.webp)
ENGLISH
25
1. General
1.1 Applications
2. Pumped liquids
3. Technical data
3.1 Electrical data
3.2 Operating conditions
3.3 Description of model properties
4. Installation and connection
4.1 Installing the pump
4.2 Electrical connections
4.3 Starting
4.4 Starting the pump after a long
period of inactivity
5. Control and regulation panels
Active System
5.1 Front control and regulation panel
5.2 Internal regulation panel
5.3 Dip-Switch for selecting functions
6. Pressure and flow switch function
Pressure boosting function
RWS Function (rainwater collection)
6.1 Dip-Switch regulation
6.2 Single pump operation
Operation of sets of 2 electropumps
7. Pressure and flow switch function
RWS Function (rainwater collection)
Start and Stop pressure regulation
7.1 Dip-Switch regulation
7.2 Dip-Switch regulation for choosing
pressure vales in the Pressure and flow
switch function.
Single pump regulation
Regulation of sets of 2 electropumps
8. RWS Function (rainwater collection)
8.1 Dip-Switch regulation
8.2 RWS operation
8.3 Intervention against dry operation
with external input inactive
8.4 Intervention against dry operation
with external input active
8.5 Checking the system
9. Pressurise boosting function
Start and Stop pressure regulation
9.1 Dip-Switch regulation
9.2 Dip-Switch regulation for choosing
pressure values
Single pump regulation
Regulation of sets of 2 electropumps
10. Protections and alarms
10.1 OVERPRESSURE alarm
10.2 EXTERNAL INPUT alarm
10.3 DRY RUNNING alarm
10.4 ANTICYCLING protection
10.5 DIP-SWITCH INCOHERENCE alarm
10.6 COMMUNICATION ABSENT alarm
IN SETS OF 2 PUMPS
10.7 ANTIFREEZE function
11. Troubleshooting
Spare electronic card
Diagram of load losses
Page
25
25
25
25
25
25
26
26
26
27
27
27
28
28
29
30
31
31
31
31
31
31
31
31
32
32
32
32
32
32
32
32
32
32
32
33
34
34
34
34
34
34
34
35
36
217
1. GENERAL
Read this documentation
carefully before installation.
Installation, electrical connection and commissioning must
be carried out by skilled personnel in compliance with the
general and local safety regulations in force in the country
of installation of the product. Failure to comply with these
instructions not only causes risk to personal safety and
damage to the equipment, but invalidates every right to
assistance under guarantee.
The appliance is not intendend for use by persons
(including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction
concerning use of the appliance by a person responsable
for their safety. Children should be supervised to ensure
that they do not play with the appliance.
1.1 Applications
ACTIVE
is a compact pressure boosting system composed
of a pump, a motor and a built-in control unit, which can
also be installed outside.
It is used in particular for increasing the pressure in
storage tanks and for water supply:
- in domestic pressure boosting systems,
- for small farming and gardening applications,
- for industrial services and systems,
- for washing systems and hobby applications.
The pump can be used for pumping rainwater, drinking
water and non drinking water.
2. PUMPED FLUIDS
The machine has been designed and built for pumping
water, free from explosive substances and solid particles
or fibres, with a density of 1000 kg/m³ and a kinematic
viscosity of 1 mm²/s, and chemically non-aggressive
liquids.
Small sand impurities of 5-10 gr./m³ - Ø 1 mm are
accepted.
3. TECHNICAL DATA
3.1 Electrical data
- Supply voltage:
1x220-240V 50/60Hz
- Max. current:
6,5 A
- Degree of protection:
IP55 Active – IP44 Motor
- Insulation class:
F
- Power cable:
1,5 mt H05 RN-F
with/without plug
3.2 Operating conditions
- Range of operation:
0,3 ÷ 8,4 m³/h
- Head up – Hmax (m):
page 218
- Liquid temperature:
0 ÷ 35°C domestic use
(EN 60335-2-41)
- Environment temperature:
0 ÷ 40°C
- Storage temperature:
-10 ÷ 40°C
- Maximum working pressure:
8 bar (800 Kpa)
- Relative humidity in air:
Max. 95%
- Connections:
1” GAS / NPT
- Noise level:
Directive EC 89/392/EEC
Summary of Contents for ACTIVE JI 62
Page 91: ...87 Active 1 GAS 50Hz 1 NPT 60Hz GAS 4 2 5 4 3 4 4 H2 0...
Page 92: ...88 5 ACTIVE SYSTEM 5 1 ACTIVE ON 2...
Page 99: ...95 11 ANAZHTH 45 C...
Page 100: ...96 4...
Page 114: ...110 3 3 Active J Active JI Active JC Active E Active EI Active EC 8 8 10 4 4 1 40 C 4...
Page 115: ...111 Active 1 GAS 50 1 NPT 60 GAS 4 2 5 4 3 4 4 H2 0...
Page 116: ...112 5 ACTIVE SYSTEM 5 1 ACTIVE 2...
Page 118: ...114 5 3 ON OFF 1 2 RWS RWS 3 3 4 5 3 5 8 1 5 3 1 5 6 4 1 3 8 5 6 7 5 1 8...
Page 123: ...119 11 45 C...
Page 124: ...120 4...
Page 139: ...135 Active 1 GAS 50 Hz 1 NPT 60 Hz GAS 4 2 5 4 3 4 4 H2 0...
Page 140: ...136 5 ACTIVE SYSTEM 5 1 ACTIVE ON ALARM Start Stop 2...
Page 147: ...143 11 45 C...
Page 148: ...144 4 OR...
Page 186: ...182 3 3 Active J Active JI Active JC Active E Active EI Active EC 8 8 10 4 4 1 40 4...
Page 187: ...183 1 GAS 50 1 NPT 60 GAS 4 2 5 4 3 4 4 H2 0...
Page 188: ...184 5 ACTIVE SYSTEM 5 1 ACTIVE ON ALARM Start Stop 2 START...
Page 195: ...191 11 45...
Page 196: ...192 4 OR...
Page 223: ......