DXS-3600 Series 10GbE Layer 2/3 Switch CLI Reference Guide
502
Remote Network MONitoring (RMON) Commands
51-1 rmon collection stats
This command is used to add a statistic entry. Use the no form of this command to remove a statistic entry.
rmon collection stats
index
[owner
ownername
]
no rmon collection stats
index
Parameters
51-2 rmon collection history
This command is used to add a history entry. Use the no form of this command to remove a history entry.
rmon collection history
index
[owner
ownername
] [buckets
bucket-number
] [interval
seconds
]
no rmon collection history
index
Parameters
index
Specifies the statistic index in the range of 1 to 65535.
owner
ownername
Specifies the string that describes the owner name information. The maximum length
is 127 characters (please refer to the RFC1213 for more information about the
maximum length
parameter).
Default
None.
Command Mode
Interface Configuration Mode.
Command Default Level
Level: 12
Usage Guideline
At the present, this switch supports only the statistics of the Ethernet interface. Add
an RMON collection statistic for the specified interface on the switch.
Example
This example shows how to add a statistic entry.
DXS-3600-32S#configure terminal
DXS-3600-32S(config)#interface tenGigabitEthernet 1/0/1
DXS-3600-32S(config-if)#rmon collection stats 100
DXS-3600-32S(config-if)#
Example
This example shows how to remove a statistic entry.
DXS-3600-32S#configure terminal
DXS-3600-32S(config)#interface tenGigabitEthernet 1/0/1
DXS-3600-32S(config-if)#no rmon collection stats 100
DXS-3600-32S(config-if)#
index
Specifies the history index in the range of 1 to 65535.
owner
ownername
Specifies the string that describes the owner name information. The maximum length
is 127 characters (please refer to RFC1213 for the maximum length in detail).
buckets
bucket-number
Specifies the used data source and time interval. Each sampling interval should be
sampled once. The sampling results are saved. The
bucket-number
specifies the
maximum number of sampling. When the maximum is reached for the sampling
records, the new one will overwrite the earliest one. The value range of Bucket-
number is 1 to 65535. Its default value is 50.
interval
seconds
Specifies the sampling interval in the range of 1 to 3600 seconds, 1800 seconds by
default.
Summary of Contents for DXS-3600-16S
Page 1: ...CLI Reference Guide Product Model DXS 3600 Series Layer 2 3 Managed 10GbE Switch Release 1 10 ...
Page 232: ...DXS 3600 Series 10GbE Layer 2 3 Switch CLI Reference Guide 224 ...
Page 301: ...DXS 3600 Series 10GbE Layer 2 3 Switch CLI Reference Guide 293 ...
Page 349: ...DXS 3600 Series 10GbE Layer 2 3 Switch CLI Reference Guide 341 ...
Page 494: ...DXS 3600 Series 10GbE Layer 2 3 Switch CLI Reference Guide 486 ...
Page 564: ...DXS 3600 Series 10GbE Layer 2 3 Switch CLI Reference Guide 556 ...
Page 649: ...DXS 3600 Series 10GbE Layer 2 3 Switch CLI Reference Guide 641 ...