DXS-3600 Series 10GbE Layer 2/3 Switch CLI Reference Guide
137
7-81 show ip bgp inconsistent-as
This command is used to display the routes which have the same prefix and different AS path origins.
show ip bgp inconsistent-as [{all | rd
ASN:NN
| vrf
VRF-NAME
}]
Parameters
LocPrf
Local preference value as set with the set local-preference route-map configuration
command. The default value is 100.
Weight
Weight of the route as set via autonomous system filters.
Path
Autonomous system paths to the destination network.
all
(Optional) Specifies to display routes of all VPN and VRFs.
rd
ASN:NN
(Optional) Specifies to display routes with the specified Route Distinguisher. The
ASN:NN can be
IP address:number
or
AS number:number
.
vrf
VRF-NAME
(Optional) Specifies the VRF name. The length of the
VRF-NAME
is 12 characters.
Default
None.
Command Mode
Privileged Mode.
Command Default Level
Level: 3. (
EI Mode Only Command
)
Usage Guideline
This command displays the routes which have inconsistent-as originating
autonomous systems.
Example
This example shows the output from the
show ip bgp inconsistent-as
command, in
privileged mode.
DXS-3600-32S#show ip bgp inconsistent-as
BGP Local Router ID is 10.90.90.10
Status codes: s suppressed, d damped, h history, * valid, > best, i - internal
Origin codes: i - IGP, e - EGP, ? – incomplete
IP Address/Netmask Gateway Metric LocPrf Weight Path
* 40.58.0.0/16 103.1.10.1 0 0 200 i
*>i 20.1.1.1 0 100 0 i
* 40.59.0.0/16 103.1.10.1 0 0 200 i
*>i 20.1.1.1 0 100 0 i
* 40.60.0.0/16 103.1.10.1 0 0 200 i
*>i 20.1.1.1 0 100 0 i
DXS-3600-32S#
Display Parameters
Description
Summary of Contents for DXS-3600-16S
Page 1: ...CLI Reference Guide Product Model DXS 3600 Series Layer 2 3 Managed 10GbE Switch Release 1 10 ...
Page 232: ...DXS 3600 Series 10GbE Layer 2 3 Switch CLI Reference Guide 224 ...
Page 301: ...DXS 3600 Series 10GbE Layer 2 3 Switch CLI Reference Guide 293 ...
Page 349: ...DXS 3600 Series 10GbE Layer 2 3 Switch CLI Reference Guide 341 ...
Page 494: ...DXS 3600 Series 10GbE Layer 2 3 Switch CLI Reference Guide 486 ...
Page 564: ...DXS 3600 Series 10GbE Layer 2 3 Switch CLI Reference Guide 556 ...
Page 649: ...DXS 3600 Series 10GbE Layer 2 3 Switch CLI Reference Guide 641 ...