DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Switch CLI Reference Manual
69
DES-3028P:4#create syslog host 1 severity all
facility local0
Command: create syslog host 1 severity all facility
local0
Success.
DES-3028P:4#
config syslog host
Purpose
Used to configure the syslog protocol to send system log data to a remote host.
Syntax
config syslog host [all | <index 1-4>] {severity [informational | warning | all] | facility
[local0 | local1 | local2 | local3 | local4 | local5 | local6 | local7] | udp_port
<udp_port_number> | ipaddress <ipaddr> | state [enable | disable]
Description The
config syslog host
command is used to configure the syslog protocol to send system
log information to a remote host.
<index 1-4>
Specifies that the command will be applied to an index of hosts. There are
four available indexes, numbered 1 through 4.
ipaddress <ipaddr>
Specifies the IP address of the remote host where syslog messages
will be sent.
severity
Severity level indicator. These are described in the following:
Bold
font indicates that the corresponding severity level is currently supported on the
Switch.
Numerical Severity
Code
0 Emergency: system is unusable
1 Alert: action must be taken immediately
2 Critical: critical conditions
3 Error: error conditions
4 Warning: warning conditions
5 Notice: normal but significant condition
6 Informational: informational messages
7 Debug: debug-level messages
Parameters
informational
Specifies that informational messages will be sent to the remote host. This
corresponds to number 6 from the list above.
warning
Specifies that warning messages will be sent to the remote host. This
corresponds to number 4 from the list above.
all
Specifies that all of the currently supported syslog messages that are generated by the
Switch will be sent to the remote host.
facility
Some of the operating system daemons and processes have been assigned
Facility values. Processes and daemons that have not been explicitly assigned a Facility
may use any of the "local use" facilities or they may use the "user-level" Facility. Those
Facilities that have been designated are shown in the following: Bold font indicates the
facility values the Switch currently supports.