6
KCU-1P Power up
At power up, the front LED shows the status of the KCU-1P.
Power up sequence:
●
RED:
48V power present but no USB connection.
●
ORANGE:
Connected to the PC USB port, drivers are installed. The unit is ready to operate.
●
GREEN:
Active Motion.
NOTE
:
One KCU-1P can provide the motion signal for a maximum of 20 daisy-chained ACM G3.
A
CTUATOR
C
ONTROL
M
ODULE
ACM
G3
families and compatibility
There exists multiple ACM in the G3 architecture. The following table outlines the ACM G3 compatibility with
different actuator models.
ACM
G3
TRAVEL
MODEL
MAX NUMBER OF
ACTUATORS PER ACM
ACM
G3
w DISCHARGE
Master, Slave
1.5 in
250i
2
400i
250HD
400HD
3 in
250i-3
2
400i-3
ACM
G3
w DISCHARGE & FAN
Master, Slave
6 in
500HD
2
NOTE
: ACMs are programmed to work with a specific actuator model and at a specific place in
the architecture (Master/Slave). Thus, ACMs are not interchangeable.
NOTE
: In the G3 architecture, the ACMs are only compatible with a G3 actuator (motor and
mechanics). Different generations of components are not compatible with each other.