20
Removal
Unscrew bolt (4) with the ½ hex key and remove
washer (3) and pivot (2) from the actuator (1).
Apply threadlocker Loctite 263 to the threaded
section of bolts (3) and ball joint (4).
Install pivot (2) on actuator (1) with bolts (3). Torque
bolts to 50 lbf in.
Screw the threaded section of ball joint (4) in the
actuator (3). Use a torque wrench with a 5/8 crow
foot socket to tighten the ball joint (4) in the
actuator. Torque to 170 lbf in.
Place spacer (5) at its required location.
Make sure the holes in the spacer are aligned with
the holes in the floor and place the actuator and ball
joint assembly in spacer (5).