9
ACM
G3 LED Status
ACM
G3
LED STATUS
Off
ACM not powered
Green
No fault
Flashing green & flashing orange/red (MASTER)
Fault on one ACM
Red
Actuator fault. Manual re-initialization required.
Orange
Actuator fault. The unit will reinitialize by itself after a
few minutes.
A
CTUATOR
Maximum axial load
The following table shows the maximum axial load for each actuator.
TRAVEL
ACTUATOR MODEL
(mechanics name)
MAX AXIAL LOAD lb
MAX AXIAL LOAD
1
N
D-BOX
– System Monitor
1.5 in
250HD (AC10)
250
1900
400HD (AC10)
400
2400
250i (AC218)
250
1900
400i (AC218)
400
2400
3.0 in
250i-3 (AC231)
250
1900
400i-3 (AC231)
400
2400
6.0 in
500HD-6 (AC360)
500
2800
1
You can find the reference to the maximal axial load in System Monitor - part of Motion
Core. The Newton units are a reference to the load perceived by each motor but can’t be
converted into actual Newtons. Therefore D-BOX uses the eponym index.
Make sure that the weight on the platform is no higher than the maximum supported weight.
Make sure that the weight is evenly distributed among the actuators of the platform (as centered as
possible).