GATE EVALUATION
It is extremely important to evaluate the gate that is to be automated before any automation is done. The
following points must be checked. All of the points mentioned below are common causes of problems if
not checked.
Ensure that the end stops are secure.
It is recommended that steel plates
of a minimum 70mm high are used as
stops.
Ensure that the wheels are turning freely
.
It is recommended that 16mm round bar is used to assist
with the smooth operation of the gate
The gate must not move on its own when left in any position on the
rail.
D.A.C.E will not be held responsible for any gates bumping
the ends stops when a gate is automated on a slide!
Ensure that the gate is level!
Rollers must roll freely.
The roller mounting can be used as an antilift device.
All precautions must be taken to ensure that
the gate cannot run free of the rollers.
A device can be fabricated and fitted to
prevent this.
The gate must not bind in any way on
the bracket when opening or closing.
Binding can cause a fuse to blow.
The catch bracket can also be used
as an antilift device