SOFTUNE Workbench Getting Started
FR Family FR81S Series, Emulation System, Doc. No. 002-04887 Rev. *A
28
5.2.4
Automatic Flash Synchronisation
Usually during active debug session loading new compiled code is only possible, when the debug session is
stopped and the “reset” button in the GUI is pressed. In order to synchronize the changed software code with the
code inside the Flash automatically during stopped debug session, following setps must be done: Stop debug
session, enter [Setup] > [Debug Environment] > [Debug Environment...], tab [Load] and enable the tick of the
functionality [Synchronize after load] (see Figure 5-15). After that save the setting changes by close the window
with the ‘OK’.
Figure 5-15. Flash Synchronisation F
unction in ‘Setup Debug Environment’ Window
.
5.2.5
High Speed Mode
Usually the Standard clock is selected for the debug communication, which corresponds to the baud rate: Main
clock frequency divided by 8 (500kBaud @ 4MHz Main clock). In addition to standard baud rate the high speed
mod
e can be selected. The baud rate for communication direction from MCU to PC is rated to ‘PLLCK / 2’ (e.g.
40MHz baud rate @ 80MHz PLLCK clock).