![CYP SDV-CS8 Operation Manual Download Page 41](http://html1.mh-extra.com/html/cyp/sdv-cs8/sdv-cs8_operation-manual_2704825041.webp)
41
COMMAND
Description and Parameters
get uart N1 stop bit
Show the current number of stop bits for the specified serial port.
Available values for
N1
:
1 [3-pin serial port]
2 [5-pin serial port]
set uart N1 data bit N2
Set the data bits used by the specified serial port.
Available values for
N1
:
1
[3-pin serial port]
2
[5-pin serial port]
Available values for
N2
:
7
[7 data bits]
8
[8 data bits]
get uart N1 data bit
Show the current number of data bits used by the specified serial
port.
Available values for
N1
:
1
[3-pin serial port]
2
[5-pin serial port]
set uart N1 parity N2
Set the parity of the specified serial port.
Available values for
N1
:
1
[3-pin serial port]
2
[5-pin serial port]
Available values for
N2
:
0 [None]
1 [Odd]
2 [Even]