![CYP SDV-CS8 Operation Manual Download Page 20](http://html1.mh-extra.com/html/cyp/sdv-cs8/sdv-cs8_operation-manual_2704825020.webp)
20
input, drag the IR input down to the “Stop” button at the bottom
of the window, then release the mouse button. To stop the
transmission of ALL IR signals, drag the “All” button down to the
“Stop” button.
■
IR Output:
This section provides drag-and-drop buttons for all
IR output ports detected by the system. Each IR output has an
automatically assigned IR stream IP address listed below the
output’s name.
IR Output to IR Input Routing:
To connect an IR output to an
IR input, click and drag the IR output’s button on the right to the
preferred IR input on the left side, then release the mouse button.
If the routing was completed successfully, the newly routed IR
output’s IR stream IP address will appear below the IR input’s name
within its button. Clicking on any IR output button will change the
colour of itself, and all IR inputs currently routed to it.
Note: IR inputs may also be drag and dropped onto IR outputs to
activate a new route.
6) RS-232 Routing:
Provides drag-and-drop control over the routing
of the RS-232 senders and receivers detected on all transmitters and
receivers. The RS-232 port on a standard extension unit contains one
sender (Rx pin) and one receiver (Tx pin).
Note: An RS-232 receiver can be routed to by multiple RS-232 senders,
however each RS-232 sender may only be directly routed to a single
RS-232 receiver. If an RS-232 sender needs to be sent to more than one
receiver, the Global Broadcast option must be used.