Curtis 1356/1356P CAN Expansion Module Manual,
Rev. A
45
DRIVER OUTPUT PROGRAM MENU
*
ALLOWABLE
PARAMETER
RANGE
DESCRIPTION
Operation Mode
0 – 3, 5 – 7
Selects the driver operation mode:
0 = Active High Digital Input mode.
1 = Constant Current mode.
2 = Constant Voltage mode.
3 = Direct PWM mode.
5 = Constant Current mode (with open detection).
6 = Constant Voltage mode (with open detection).
7 = Direct PWM mode (with open detection).
Current Limit
0.00 – 3.00 A
Sets the maximum current output when the PDO
(Driver 1)
command is 100%; applicable only when the driver
0.00 – 1.00 A
is operating in Constant Current mode.
(Driver 2)
Voltage Limit
0.0 – 36.0 V
Sets the maximum voltage output when the PDO
(36V models)
command is 100%; applicable only when the driver
0.0 – 80.0 V
is operating in Constant Voltage mode.
(80V models)
PWM Limit
0.0 – 100.0 % Sets the maximum PWM output when the driver
is operating in Direct PWM mode.
Dither Period
4 – 200 ms
Sets the time between dither pulses (in 2 ms steps).
A dither period of 4 – 200 ms provides a frequency
range of 250 – 5 Hz.
Dither Amount
0 – 500 mA
Sets the amount (+/-) of dither that will be
added/subtracted from the command
(in 10 mA steps).
Kp
0.1 – 100.0 %
Sets the proportional gain factor of the PI current
controller.
Ki
0.1 – 100.0 %
Sets the integral gain factor of the PI current
controller.
*
This menu is repeated for Drivers 1 and 2.
7 — PROGRAMMER: PROGRAM MENUS
Summary of Contents for 1356
Page 2: ......