8
Curtis 1356/1356P CAN Expansion Module Manual,
Rev. A
Fig. 3
Basic wiring diagram, Curtis 1356 /1356P CAN expansion module.
2 — INSTALLATION & WIRING:
Standard Wiring Diagram
WIRING: BASIC CONFIGURATION
A basic wiring diagram is shown in Fig. 3, and described below. The diagram
shows the standard power and battery connections, as well as some basic uses
for the inputs and outputs.
Power Connection
The battery is connected to the module’s B+ pin though a fuse, a diode, and a
keyswitch. The fuse protects the wiring in the event of a short or failure. The
return path of the coils is also brought back to the B+ pin to utilize the flyback
diodes connected inside the module between B+ and each driver output.
The keyswitch is used to turn on the system. When the keyswitch is closed,
B+ goes high and the 1356 /1356P’s power supply brings up the module.
J1-11
J1-23
J1-13
J1-1
J1-2
J1-14
J1-3
J1-15
J1-4
J1-16
J1-5
J1-17
J1-6
J1-12
KEYSWITCH
SWITCH
BATTERY
(12–80V)
REVERSE
POLARITY
PROTECTION
PROPORTIONAL
VALVE
CONTACTOR
CAN PORT
1356 / 1356P
ENCODER A
ENCODER B
ANALOG INPUT 1
ANALOG INPUT 2
ANALOG INPUT 3
OUTPUT 1
OUTPUT 2
INPUT 3
INPUT 4
INPUT 5
INPUT 6
INPUT 7
INPUT 8
INPUT 9
CAN H
CAN L
+5V
ENCODER
J1-10
J1-22
J1-20
J1-9
J1-21
0–15V IN
RESISTIVE THROTTLE,
RTD, etc.
J2-4
J2-3
J2-1
SERIAL PORT
(4-pin Molex)
4
3
1
2
840
DISPLAY
8
6
5
+12V
RX
TX
J1-18
J1-7
J1-19
J1-8
INPUT 10
INPUT 11
INPUT 12
INPUT 13
J2-2
I/O GND
I/O GND
J1-24