Curtis 1356/1356P CAN Expansion Module Manual,
Rev. A
21
PDO1-MISO
(sent in response to the system master)
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
Input
Input
5 Virtual [Reserved]
Analog Analog Analog Analog
1–8 9–13 Inputs
(0)
Input 4
Input 4
Input 5
Input 5
Status Status
Voltage Voltage
Voltage
Voltage
Value Value Value Value
Low Byte High Byte Low Byte High Byte
PDO2-MISO
(sent in response to the system master)
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
Analog Analog Analog Analog Analog Analog
[Reserved]
[Reserved]
Input 1
Input 1
Input 2
Input 2
Input 3
Input 3
(0)
(0)
Voltage Voltage Voltage Voltage Voltage Voltage
Value Value Value Value Value Value
Low Byte High Byte Low Byte High Byte Low Byte High Byte
Output Command Bytes
The drivers are closed-loop controlled, either for current or voltage. This byte
sets the output command as a percent of the programmed output limit value:
0 – 255 = 0% – 100%.
BDI
The BDI value is a percent of the battery state of discharge: 0–100 = 0–100%;
this value is gotten from the CAN master.
Inputs 1–13 Status Bytes
The 1356 /1356P monitors the thirteen digital inputs. The status of these inputs
in default PDO-MISO mapping is as follows.
PDO1-MISO Byte 1
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
Digital Digital Digital Digital Digital Digital Digital Digital
Input8 Input7 Input6 Input5 Input4 Input3 Input2 Input1
Status Status Status Status Status Status Status Status
PDO1-MISO Byte 2
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
[Reserved] (0) Digital Digital Digital Digital Digital
Input13 Input12 Input11 Input10 Input9
Status Status Status Status Status
A status of 1 (bit set) indicates that the input is active (pulled high to B+). The
upper three bits of Byte 2 are unused and set to 0.
4 — PDO COMMUNICATIONS