Appendix D: Safety Characteristics and Certification
• Performance criterion A — During test normal performance within the specification limits
• Performance criterion B — During test, temporary degradation, or loss of function or performance
which is self-recovering
• Performance criterion C — During test, temporary degradation, or loss of function or performance
which requires operator intervention or system reset occurs.
Normal operation (load cell connected)
Percentage
Allowable weight variation of EDGE Bin Scale 4 Wires
LC
0.6% error from the EDGE Bin Scale plus combined
errors caused by the load cell model
(typical error percentage: 1,7% to 2,8%)
3,4% max of full scale
Allowable weight variation of EDGE Bin Scale 3 Wires
LC
Greater than 3,4% of full scale
Allowable loss of performance in a noisy
environment
Percentage
Allowable noise on EXC+ on EDGE Bin Scale 4 wires
Lc
0.7% error from the EDGE Bin Scale plus combined
errors caused by the load cell model
(typical error percentage: 1,7% to 2,9%)
3,5% max of full scale
Allowable weight variation due to noise on SIG+ on
EDGE Bin Scale 3 wires Lc
Greater than 3,5% of full scale
EDGE Bin Scale element
Normal operation
Allowable loss of performance
RS-485 link
1 communication frame loss
3 consecutive communication frames losses
OLED display
No visual degradation
No visual degradation
Environment characteristics
Parameter
Condition
Value
Environment Location
Inside and outside
Operating Temperature
Operating
-40 to 40°C (-40 to 104°F)
Storage
-40 to +50°C (-40 to +122°F)
Humidity (Maximum Relative)
-40 to 0°C (-40 to 32°F)
Non condensing
0 to 10°C (32 to 50°F)
Non condensing
10 to 30 °C (50 to 86 °F)
95 % (± 3%) Non condensing
30 to 40 °C (86 to 104 °F)
95 % (± 3%) Non condensing
Storage
Non condensing
Altitude
2000 Meters Max. (6561 Ft. Max)
Electromagnetic Environment
EN/IEC61326-1, IEC EN 60730-1, EN
61000-6-4, EN 61000-6-2
Enclosure Protection
Nema 250 : type 4x IP : 66, ref : IEC60529
Impact rating (IK)
08
891–00577
EDGE Bin Scale 3 Wires LC
73
Summary of Contents for 074-11772
Page 26: ...NOTES 26 891 00577 EDGE Bin Scale 3 Wires LC...
Page 34: ...Chapter 3 Basic connections Figure 3 3 Loadcell Wiring 34 891 00577 EDGE Bin Scale 3 Wires LC...
Page 38: ...NOTES 38 891 00577 EDGE Bin Scale 3 Wires LC...
Page 48: ...Chapter 6 Setup Figure 6 2 Tank group setup screen 48 891 00577 EDGE Bin Scale 3 Wires LC...
Page 59: ...891 00577 EDGE Bin Scale 3 Wires LC 59...
Page 64: ...NOTES 64 891 00577 EDGE Bin Scale 3 Wires LC...
Page 66: ...NOTES 66 891 00577 EDGE Bin Scale 3 Wires LC...
Page 68: ...NOTES 68 891 00577 EDGE Bin Scale 3 Wires LC...
Page 78: ...NOTES 78 891 00577 EDGE Bin Scale 3 Wires LC...
Page 80: ...NOTES 80 891 00577 EDGE Bin Scale 3 Wires LC...
Page 82: ...NOTES 82 891 00577 EDGE Bin Scale 3 Wires LC...
Page 84: ...NOTES 84 891 00577 EDGE Bin Scale 3 Wires LC...
Page 88: ...NOTES 88 891 00577 EDGE Bin Scale 3 Wires LC...
Page 90: ...NOTES 90 891 00577 EDGE Bin Scale 3 Wires LC...
Page 94: ...NOTES 94 891 00577 EDGE Bin Scale 3 Wires LC...
Page 100: ...NOTES 100 891 00577 EDGE Bin Scale 3 Wires LC...