A
CUES Inc.
,
MPlus+ User Manual | CH905
85
www.cuesinc.com
,
APPENDIX A
LIGHTS POWER FAULT: HIGH V:
If the lights power voltage was measured at more than 31.02 Volts, the lights power supply
is shut down and this message will be displayed.
SCREEN NOT AVAILABLE:
This message appears if attempting to move to a screen for Mini Pan &Tilt diagnostics
without having a Mini Pan & Tilt camera.
UNHANDLED EXCEPTION PWR DOWN:
This message will only be displayed if the firmware has an unresolved error.
UNSUPPORTED USB DEVICE:
This message will be displayed if the firmware detects something other than the keyboard
during normal operation, or a suitable thumb drive when performing a firmware update.
USB COMMUNICATION ERROR:
This message will be displayed if the firmware has difficulty communicating with a USB device.
WARNING: BATTERY OVERCURRENT:
If the battery current is measured at more than 8.0 A, this message will be displayed.
WARNING: IN5VB ERROR:
If the internal CH412 board’s ‘+5VB’ supply is measured at more than 3% away from 5.0
Volts, this message will be displayed.