A
84
CUES Inc.
,
MPlus+ User Manual | CH905
www.cuesinc.com
,
APPENDIX A
STATUS MESSAGE DESCRIPTIONS:
Many of the messages displayed are self-explanatory. Here are some that may benefit
from additional information:
ATTEMPTING MP&T RECONNECTION:
Communication with the MP&T camera has not been established. The firmware will
continue to display this message every 5 seconds while it is not able to connect.
CODE CAN’T BE ALL SPACES:
When creating a custom code, there must be at least one non-space character in it.
CUSTOM LIST IS EMPTY:
This message is displayed when the operator attempts to view or delete a custom code
list that is empty and after deleting the last entry from a custom list.
DVR NOT READY:
The internal DVR module requires 25 seconds to initialize after power-up. Attempting
to adjust the microphone or speaker, or to display the DVR menu during this period will
cause this message to be displayed.
FUNCTION NOT AVAILABLE:
Any time the operator tries to do something for which he doesn’t have the proper
equipment, e.g. move the Mini Pan & Tilt camera when he isn’t using one, he will receive
this message. It is also displayed when trying to toggle the DVR when on the GXP screen.
GAUGE ON DUE TO LOW BATTERY:
The battery gauge can only be turned off if the battery has more than 10% charge remaining.
NO MORE ROOM IN LIST:
Only 50 custom codes may be created. Attempting to add a custom code once there are
already 50 codes will cause this message to be displayed.
CAMERA POWER FAULT: HIGH I:
If the current being drawn from camera power was measured at more than 0.45 amps,
the camera power is shut down and this message will be displayed.
CAMERA POWER FAULT: HIGH V:
If the camera power voltage was measured at more than 31.02 Volts, the camera power
supply is shut down and this message will be displayed.
LIGHTS POWER FAULT: HIGH I:
If the lights power being drawn was measured at more than 1.125 amps, the lights power
supply is shut down and this message will be displayed.