Level control (upon request)
If the dosing pump is supplied with level control setting and upon request floating level switch. When the level of the additive
is lower than the switch, level alarm goes ON, the display will show "FAO", the pump is off giving an optical and sound alarm. The
level control alarm goes ON with 5 seconds delay.
Calibration
Turning on the pump, the instrument switches automatically to the "METER" function.
Pressing button mA pulse (5) will show the actual mA input signal. To go back to strokes/min press again. The manual function
is also used when priming the pump. In order to avoid programming and setting errors during the system functioning, the pump is
programmed to automatically return to the Meter Mode each time the unit is switched OFF..
PARAMETERS SETTING MODE
” MANUAL ” Mode
Turn pump ON
A. On the control panel press button F (14) and start manual mode: (“Manual” LED 2 ON )
B. By means of button 10 (increase) and 3 (decrease), select the number of imp/min. To prime the pump set pulse rate at
75%.
C. Prime the pump.
” SET1 ” Mode
Mode Set 1 is used to select the mA input value/min. dosing pump flow and pulse frequency:
A.
Press button 14; Set 1, LED ON. The display will show the pulse frequency previously set.
B.
Select the minimum pump output required pressing buttons 3 and 10. If the minimum output is zero set 000.
C.
Press button 5 “mA” LED ON:
D.
By pressing buttons 3 and 10, you can select the mA input value corresponding to minimum pump output required.
Confirm with enter 11. To finish the programming procedure and modify the maximum output value, press button 14 which
will automatically change to mode Set 2.
” SET2 ” Mode
Mode Set 2 selects the mA input value/max. dosing pump flow and pulse/frequency.
A.
Press button 14 Set 2 LED ON, the display will show the frequency previously set.
B.
Press buttons 3 and 10 to set the desired imp/frequency at the maximum pump output required.
C.
Press button 5 “mA/pulse”, the display will show the value previously set.
D.
Pressing 3 and 10 select the mA input value at the maximum pump output required.
E.
Press button 11 to enter. The pump will automatically return to “METER” mode and is operational according to the
selected functioning mode; two modes are available: direct/reverse.
“Direct” Functioning Mode
During production the pumps are programmed for a 4-20 mA direct functioning curve. The pump will start every time the
mA signal goes above 4 mA increasing the pulse frequency (and consequently the flow) pro-portionally to the mA input signal
up to maximum imp/min frequency available. E.G. Set 1 minimum signal 4 mA, minimum output. Set 2 maximum signal 20
mA, maximum output.
74
ENGLISH
Summary of Contents for BOMBAPRO PH-RX
Page 2: ......
Page 7: ...Limpieza y mantenimiento del electrodo 30 DIBUJOS 117 Bomba 117 Cuerpo bomba 118 ESPAÑOL 7 ...
Page 32: ......
Page 35: ...DISEGNI 117 Pompa 117 Corpo Pompa 118 ITALIANO 35 ...
Page 60: ......
Page 63: ...DRAWINGS 117 Pump 117 Pump head 118 ENGLISH 63 ...
Page 88: ......
Page 91: ...DESSINS 117 Pompe 117 Corps de pompe 118 FRANÇAIS 91 ...
Page 116: ......
Page 119: ......
Page 120: ...CDMU 00203ML1A 03 2016 ...