C) Locate the pump as shown in fig. 5 bearing in mind that it may be installed either below or above the level of the liquid
to be dosed, though the level difference should not exceed 2 meters. When the process plant in which the pump is installed is
operating at atmospheric pressure (no back pressure) and the chemical tank is situated above the plant (Fig. 6), the condition
of the injection valve should be checked at regular intervals, because excessive wear and tear could cause additive to drip
into the plant even when the pump is shut down. If the problem persist, install a properly calibrate counter-pressure valve
(C) between injection point and the valve. In the case of liquids that generate aggressive vapours, do not install the pump
above the stor-age tank unless the latter is hermetically sealed.
Fig. 5
Fig.6
D) The discharge nipple will always remain in the upper part of the pump. The suction nipple, which serves to attach the
hose (with filter) leading into the chemical tank, will therefore always be situated in the lower part of the pump.
Fig. 7
E) Remove the protection caps from the two nipples, slide the hoses over the connectors, pushing them
right home, and then fix them with appropriate tube nuts. (Fig. 7).
Fig. 8
68
ENGLISH
Summary of Contents for BOMBAPRO PH-RX
Page 2: ......
Page 7: ...Limpieza y mantenimiento del electrodo 30 DIBUJOS 117 Bomba 117 Cuerpo bomba 118 ESPAÑOL 7 ...
Page 32: ......
Page 35: ...DISEGNI 117 Pompa 117 Corpo Pompa 118 ITALIANO 35 ...
Page 60: ......
Page 63: ...DRAWINGS 117 Pump 117 Pump head 118 ENGLISH 63 ...
Page 88: ......
Page 91: ...DESSINS 117 Pompe 117 Corps de pompe 118 FRANÇAIS 91 ...
Page 116: ......
Page 119: ......
Page 120: ...CDMU 00203ML1A 03 2016 ...