SETPOINT Menu
CALIBRATION Menu
ALARMS Menu
SETPOINT setting
To have the pump operative it's mandatory set the following data: Setpoint values, type of dosing, manual or proportional
dosing and flow rate percentage.
SETPOINT value
From measuring status, pressing OK, the pump will
go in SETPOINT programming phase. Setpoint icon
will flash. Pressing OK again, the setpoint value
saved will flash and can be adjusted using + and -
buttons. Pressing OK, the setpoint value will be
memorized.
The pump automatically will go in DIRECTION
menu
Direction menu
In this menu, has to set if the pump has to dose above the setpoint or below this value. For Redox if the pump has to dose up
to reach a certain quantity of oxidant, the direction arrow has to point in aloft.
To select the direction of the arrow, use the + and -
buttons. Pressing OK the direction will be
memorized.
Manual or Proportional mode
After selected direction of the dosing, the pump will show ON-OFF or PROP. flashing. With + or - buttons it's possible to shift
among them.
ON-OFF - When the pump has to dose it will run at flow rate selected by the user in Flow rate setting, and it stops at the
Setpoint
82
ENGLISH
Summary of Contents for BOMBAPRO PH-RX
Page 2: ......
Page 7: ...Limpieza y mantenimiento del electrodo 30 DIBUJOS 117 Bomba 117 Cuerpo bomba 118 ESPAÑOL 7 ...
Page 32: ......
Page 35: ...DISEGNI 117 Pompa 117 Corpo Pompa 118 ITALIANO 35 ...
Page 60: ......
Page 63: ...DRAWINGS 117 Pump 117 Pump head 118 ENGLISH 63 ...
Page 88: ......
Page 91: ...DESSINS 117 Pompe 117 Corps de pompe 118 FRANÇAIS 91 ...
Page 116: ......
Page 119: ......
Page 120: ...CDMU 00203ML1A 03 2016 ...