Display description
DESCRIPTION
1. Overdosing alarm
2. Delay at powering on
3. Setpoint setting
4. Level alarm
5. Intervention Alkaline/Oxidant/Direct
6. Intervention Acid/Reductive/Inverse
7. Alarm
8. Menu selection
9. ON-OFF operation
10. Proportional operation
11. Calibration menu
12. Impulse/minute
13. Measures
14. Calibration points
15. Flow rate percentage
16. RX measure
17. pH measure
Parameters and functions layout (pH)
FUNCTIONS
DEFAULT
Setpoint setting
7, 2 pH
Choice of the type of intervention
Acid
ON-OFF or proportional intervention selection
ON - OFF
Definition of beginning intervention value "PROP."
Setpoint ± 1 pH
Overdosing alarm setting (hours : minutes)
2:00 h:min
Parameters and functions layout (mV Rx)
FUNCTIONS
DEFAULT
Setpoint setting
650 mV
Choice of the type of intervention
Oxidant
ON-OFF or proportional intervention selection
ON - OFF
Definition of beginning intervention value "PROP."
Setpoint ± 100 mV
Overdosing alarm setting (hours : minutes)
2:00 h:min
Typical characteristics
PARAMETER
VALUE
Temperature
0÷40°C
pH measure
0÷14 pH (resolution 0,01pH)
Rx (mV) measure
-1000÷ +1400 (resolution ±1mV)
ENGLISH
77
Summary of Contents for BOMBAPRO PH-RX
Page 2: ......
Page 7: ...Limpieza y mantenimiento del electrodo 30 DIBUJOS 117 Bomba 117 Cuerpo bomba 118 ESPAÑOL 7 ...
Page 32: ......
Page 35: ...DISEGNI 117 Pompa 117 Corpo Pompa 118 ITALIANO 35 ...
Page 60: ......
Page 63: ...DRAWINGS 117 Pump 117 Pump head 118 ENGLISH 63 ...
Page 88: ......
Page 91: ...DESSINS 117 Pompe 117 Corps de pompe 118 FRANÇAIS 91 ...
Page 116: ......
Page 119: ......
Page 120: ...CDMU 00203ML1A 03 2016 ...