36
CHAPTER 3
PROVISIONING VIA TEXT MENU
already VLAN-tagged. The outer (next to source MAC and representing ISP VLAN) S-TAG (service
tag) comes first, followed by the inner C-TAG (customer tag). In such cases, 802.1ad specifies a
TPID of 0x88a8 for service-provider outer S-TAG.
<M>
Management VID
: By default this VID is 1. Set this to the VID that will be used to manage the
100AS-1
converter over Ethernet.
<T>
Tag Type
: or Tag Protocol Identifier (TPID) : a 16-bit field set to a value of 0x8100 in order to
identify the frame as an IEEE 802.1Q-tagged frame. This field is located at the same position as the
EtherType/Size field in untagged frames, and is thus used to distinguish the frame from untagged
frames.
<Z>
Go to VLAN Table Configuration Page
: This menu item brings up the static VLAN table to
review status or make additions or modifications.
<S>
Save Settings
: After making changes and before leaving this menu page, use this command to
commit the changes to the
100AS-1
.
3.6.1.1 Static VLAN Table Configuration
Select item
<Z>
to enter
VLAN Table Configuration Page.
The static
VLAN table Operation
is accessed through the
<V>
menu item.
*********************************************
*** CTC UNION TECHNOLOGIES CO., LTD. ***
*** FRM220-100AS-1 Ver:1.005 ***
*********************************************
<< Local Static VLAN Table Configuration >>
Item | VLAN ID | Port 1 | Port 2 |
<N><PageDown>:Show Next Page.
<P><PageUp> :Show Previous Page.
<DownArrow>:Show Next Item.
<UpArrow> :Show Previous Item.
<V> :VLAN Table Operation.
<R> :Reset Static 802.1Q VLAN Settings.
<C> :Clear Static 802.1Q VLAN Table.
<ESC>:Go to Port VID Configuration Page.