5.12
Timed Recording
Figure 47:
Timed Recording
application
Timed Recording
provides a mechanism to record detail diagnostic data at a specified
time. Select the meter point for which the recording must be made. Choose between
starting to record immediately or starting at a scheduled time. Select the recording
duration (< 1 minute). Recordings can be repeated with a specified interval. The
interval must be at least as long as the recording duration. Finally, select the types of
data that must be captured by the recording and press
Commit
. While the
recording is in progress
Realtime View
will display the event type as “Timer”. A
scheduled recording or a recording in progress can be cancelled by pressing
Stop
.
Scheduling a new recording will overwrite a previously scheduled one.