Section 4. Management over Console Port
"Sensor input" Command
"
Sensor input
" command switches the remote device alarm generation mode from ex-
ternal sensor. The external sensor has two operating modes: "Alarm on closed" (default)
and "Alarm on open". In "Alarm on closed" mode, when the external input sensor con-
tacts are closed, remote device goes into alarm state. (For more details see section 3.2
"
Alarms
").
"Factory settings" Command
"
Factory settings
" command restores device modes to their initial state:
• E1 port use mode – all ports "In use";
• transmitted and received data strobe mode – "Normal (data valid on falling edge)";
• alarm input sensor contact mode – "Sensor input: Alarm on closed".
"Save parameters" Command
After configuring parameters (or executing "
Factory settings
" command) you should
store the parameters in non-volatile memory (NVRAM) of the multiplexer using
"Save
parameters"
command. In this case the saved parameters will be restored when the de-
vice is restarted.
"Restore parameters" Command
If parameters were changed, but not saved to NVRAM using
"Save parameters"
com-
mand, then configuration stored in NVRAM may be restored using
"Restore parameters"
command.