82
Raw Water System
8.5 Raw Water System Maintenance
The following items should be done routinely to help
maintain your raw water system:
•
Check hoses, particularly the seawater supply
lines, for signs of deterioration. Tighten fittings
or replace deteriorated hoses and components
as necessary.
•
Periodically remove and clean the water strainer
located in the primary intake fitting for the sea
chest.
•
Periodically remove and clean the water strainer
located near the intake side of the washdown
pump. Spray pumps and thru-hull valves with
a protective oil periodically.
•
Fishboxes and livewells should be drained and
cleaned after each use.
•
Operate all valves at least once a month to keep
them operating properly.
Cleaning the washdown pump water strainer:
1. To clean the strainer, make sure the Raw Water
Pump switch is off and close the valves at the
sea chest supply hose thru-hull fittings.
2. Rotate the strainer bowl counterclockwise to
release it.
3. Remove and clean the screen with fresh water.
4.
Lubricate the O-ring lightly with silicon or Teflon
grease and reinstall the screen and strainer bowl.
Raw Water Pressure Pump & Sea Strainer
Typical Raw Water Pump Strainer Removed for Cleaning
Summary of Contents for 33 CSF
Page 1: ...Crevalle 33 CSF Owner s Manual...
Page 2: ...2...
Page 10: ...10 NOTES...
Page 14: ...14 NOTES...
Page 23: ...23 Operation...
Page 74: ...74 NOTES...
Page 78: ...78 NOTES...
Page 84: ...84 NOTES...
Page 116: ...116 NOTES...
Page 124: ...124 NOTES...
Page 130: ...130 NOTES...
Page 146: ...146 NOTES...
Page 167: ...167 MAINTENANCE LOG Appendix C Date Hours Dealer Service Repairs...
Page 168: ...168 Maintenance Log Date Hours Dealer Service Repairs...
Page 169: ...169 Appendix D BOATING ACCIDENT REPORT...
Page 170: ...170 Boating Accident Report...
Page 171: ...171 Boating Accident Report...
Page 172: ...172 NOTES...
Page 174: ...174 NOTES...
Page 180: ...180 NOTES...
Page 186: ...186...
Page 187: ...187 CAUSE AND SOLUTI...