Electrical System
6.7 DC Circuit Breakers
General
Power is distributed to some 12 volt accessories
through individual “push to reset” circuit breakers
located the battery switch panel. A heavy duty
breaker near the battery switches protects the
system from an overload. Other heavy duty circuit
breakers near the battery switches protect the
main circuits for the windlass, optional air condi-
tioner, optional refrigerator and stereo amplifiers.
Some 12 volt accessories are operated directly by
the circuit breaker or fuse. Switches fed by the cir-
cuit breakers or fuses activate other accessories.
Accessory Circuit Breakers
These “push to reset” circuit breakers are labeled
for the accessory circuit they protect. Circuit
breakers labeled ACC are reserved for additional
accessories not usually installed by the factory.
If an accessory breaker trips, the reset button
pops out and can be felt through the silicone pro-
tective cover. Press the button to reset the tripped
breaker. If the breaker trips again, find and cor
-
rect the problem before resetting the breaker.
Accessory & Main Circuit Breakers In Battery Switch Panel
A. Accessory “Push To Reset” Circuit Breakers
B. Heavy Duty Circuit Breakers
Notice:
The bilge pump and high water alarm break-
ers protect continuous power circuits for
the automatic switches. Continuous power
circuits are supplied electrical power when-
ever the batteries are connected. These cir-
cuits are not deactivated when the battery
switches are turned off.
CAUTION
PROPER FUSE OR BREAKER PROTECTION MUST BE
PROVIDED FOR ALL 12 VOLT EQUIPMENT ADDED. DO
NOT OVERLOAD THE ACCESSORY CIRCUIT BREAKERS
OR OTHER CIRCUITRY THROUGH ADDITIONAL 12 VOLT
EQUIPMENT.
Heavy Duty Circuit Breakers
DC Power is distributed to the accessory breakers,
Digital switching system, windlass and other main
circuits through heavy duty, rocker style circuit
breakers located in the battery switch panel near
the battery switches. These main circuits are deac-
tivated when the House battery switch is off.
If a heavy duty circuit breaker is tripped by an
overload, the breaker will trip. Reset the breaker
by turning it off, then back on.
B
A
Summary of Contents for 33 CSF
Page 1: ...Crevalle 33 CSF Owner s Manual...
Page 2: ...2...
Page 10: ...10 NOTES...
Page 14: ...14 NOTES...
Page 23: ...23 Operation...
Page 74: ...74 NOTES...
Page 78: ...78 NOTES...
Page 84: ...84 NOTES...
Page 116: ...116 NOTES...
Page 124: ...124 NOTES...
Page 130: ...130 NOTES...
Page 146: ...146 NOTES...
Page 167: ...167 MAINTENANCE LOG Appendix C Date Hours Dealer Service Repairs...
Page 168: ...168 Maintenance Log Date Hours Dealer Service Repairs...
Page 169: ...169 Appendix D BOATING ACCIDENT REPORT...
Page 170: ...170 Boating Accident Report...
Page 171: ...171 Boating Accident Report...
Page 172: ...172 NOTES...
Page 174: ...174 NOTES...
Page 180: ...180 NOTES...
Page 186: ...186...
Page 187: ...187 CAUSE AND SOLUTI...