4. As shown below, use the
ipt
command to display the updated IP table on the
touchpanel.
Updated IP Table
5. Proceed to “
SIMPL Windows Programming
” that begins
below
on the next page.
SIMPL Windows Programming
With a Cresnet or Ethernet connection (Serial connection does NOT require SIMPL
Windows programming), it is necessary to create a SIMPL Windows program to route the
data and to transmit the touch output destination setting to the touchpanel when the system
reboots (the default "todest" setting is RS-232). In the Configuration Manager, add the
appropriate Plug-in Control Card or DPA Module to the control system and drag in the
Cresnet or Ethernet-enabled touchpanel. (The entries in the IP Table, for IP ID and IP
Address, must be set the same as for standard operation of the touchpanel on Cresnet or
Ethernet.) Configure the devices as usual.
In the Program Manager, route the output string in the touchpanel definition to an RS-232
COM port as follows:
1. Open a “Detail View”
for the touchpanel, and click the
Serial
button. Specify a
signal name for a serial output (
mouse_cmds
on <
text-i1
> is shown below as an
example).
NOTE:
As shown, Serial Join
1
for <text-i1> will be used in step 6 of “
VT Pro-e
Programming
” that begins on page
16
.
Programmer’s Guide - DOC. 5916A
Serial Mouse Control Driver
•
13