system to recognize a network device via its serial number, which is stored in the
device’s memory. This method does not require that any devices be disconnected
from the network; Net IDs may be set with the entire Cresnet system intact. This
method requires the use of the Crestron Viewport version 3.35 or later.
Use the appropriate method to set the Net ID.
Method A (Cresnet address-settable ID)
1. Ensure that the device requiring a Net ID change is the only unit connected
to the control system.
2. Open the Crestron Viewport.
3. From the Viewport menu, select
Functions | Set Network ID
. The software
checks the baud rate and then opens the "Set Network ID" window.
4. In the "Set Network ID" window, select the device requiring a Net ID
change from the
Current Network Devices
text window.
5. Select the new Net ID for the device from the
Choose the new network ID
for the selected device (Hex)
: text box.
6. Click Set ID to initiate the change. This will display the "ID command has
been sent" window.
7. In the "Command Complete" window, click
OK
.
8. In
the
Current Network Devices
text window, verify the new Net ID code.
9. In the "Set Network ID" window, click
Close
.
NOTE:
The new Net ID code may also be verified by selecting
Diagnostic | Report
Network Devices
in the Viewport (alternately, select
F4
).
10. Repeat this procedure for each additional network device requiring a Net ID
change.
Method B (Touch Settable ID)
Before using this method, you should have a list of all current network devices and
their Net IDs, to avoid assigning duplicate IDs.
Set Net ID by TSID
These procedures are for TSID-enabled network devices during the initial
configuration of a Cresnet system or when such devices are being added/replaced.
1. Ensure that all network devices are connected to the control system.
2. Open the Crestron Viewport version 3.35 or later.
3. From the Viewport menu, select
Functions | Assign Cresnet ID by Serial
Number
. The “Set Net ID by TSID” window appears. The window is first
displayed with the data fields empty.
18
•
QuickMedia™ Matrix Switcher/Mixer: QM-MD7x2
Operations Guide - DOC. 6273