Automatic Display Control
For the DM-NVX-350, DM-NVX-351, and DM-NVX-352, the display device can be turned
on or off automatically via RS-232, IR, or CEC (Consumer Electronics Control). For the
DM-NVX-350C, DM-NVX-351C, and DM-NVX-352C, CEC can be used to automatically
turn a display device on or off.
To configure automatic display control:
1.
Click the Settings tab and then click Outputs.
2.
In the Outputs table, click Edit.
3.
In the Automatic Display Power section, enable automatic power by setting the
Automatic Power toggle switch in the On (right) position. By default, automatic
power is disabled.
4.
Set Command Interface to one of the following:
•
None
•
CEC
•
RS232 (DM-NVX-350, DM-NVX-351, and DM-NVX-352 only)
•
IR (DM-NVX-350, DM-NVX-351, and DM-NVX-352 only)
The selected interface (CEC, RS232, or IR) will send the power-on or power-off
command as specified in the Power Off (No Sync Detected) and Power On (Sync
Detected) sections discussed in step 8 below. If None is selected, no command
will be sent.
5.
(Applicable only when the DM NVX device is in Receiver mode) Set Output
Timeout to enable the display device to turn off after a predetermined period of
time in which no signal is detected. Select the desired number of seconds, or
select Custom and then set the desired Custom Output Timeout in seconds.
6.
(Applicable only when the DM NVX device is in Receiver mode) Disable or enable
Turn Off Output by setting the toggle switch in the Off (left) or On (right)
position, respectively. When Turn Off Output is enabled, the output turns off
based on the Output Timeout or Custom Output Timeout setting. When Turn Off
Output is disabled (default setting), the output remains active after the display
device is turned off.
7.
If Infrared is selected in step 2, set the IR port number (Port 1 or Port 2).
Summary of Contents for DigitalMedia DM-NVX-350
Page 6: ......