![Crestron DigitalMedia DM-NVX-350 Product Manual Download Page 20](http://html.mh-extra.com/html/crestron/digitalmedia-dm-nvx-350/digitalmedia-dm-nvx-350_product-manual_2684277020.webp)
14
•
DM-NVX-35x(C) Encoders/Decoders
Product Manual – DOC. 7839M
Settings Tab – Stream, Mode Configuration
When a different mode is selected, a prompt appears asking for confirmation that the
device be rebooted. Click Yes to reboot the device.
Device Reboot Prompt
For additional information, refer to the online help of the web interface.
Using SIMPL Windows
Using the top-level programming slot for the DM-NVX-35x(C) device, set the
<DeviceMode> analog input join to the desired mode (Receiver or Transmitter).
The default setting is Receiver.
Changing modes requires that the device be rebooted. Trigger the <Reboot> digital
input join to reboot the device. For additional information, refer to the SIMPL Windows
help file.
Automatic Point-to-Point Connectivity
Point-to-point connectivity enables a DM NVX 4K60 4:4:4 encoder to be connected
directly to a DM NVX 4K60 4:4:4 decoder to stream video, audio, and USB. Rather than
being connected to an Ethernet switch, a 1000BASE-T Ethernet port of an encoder is
connected directly to a 1000BASE-T port of a decoder. By default, point-to-point mode
is enabled (set to Auto) and can be disabled if desired.