OM_CLS_-_EN_2-0
49
CLS
Advance
Troubleshooting
Error code Description/Cause
Category
Remedy/hints
By whom
0x0ADB
Coin validator FW upgrade:
source and destination data
is not same (IAP#10). FW
file is corrupt
Attention
FW file failure, contact service
Service
0x0ADC
Coin validator FW upgrade:
flash programming hardware
interface is busy (IAP#11)
Attention
Reset CLS
Service
0x0ADD
Coin validator FW upgrade:
coin validator is in boot-
loader mode
Info
0x0ADE
CLS system tried to write
a table as specified by
validator spec but validator
returned failed table writing
error
Info
0x0ADF
CLS system wrote a table as
specified by validator spec to
validator successfully
Info
0x0B01
Coin return conveyor motor
failure. Return belt motor
was commanded to operate
but no current flow through
the motor was detected
Critical
• Connection/installation failure,
contact service
• Hardware replacement
• Service
• Service department,
CPI, Buxtehude
0x0B02
Coin return conveyor motor
overcurrent likely due to
coin jam
Attention
Eliminate coin jam or foreign objects
on the return belt
Attendant possessing
the key for the lower
lock
0x0E74
Sensors in coin input funnel
blocked during power on
Critical
• Remove coins or foreign objects
from sensors
• If necessary, clean coin input
funnel
(cf. Chap. "8.4.1 Cleaning the
housing, coin input funnel and return
tray", p. 36)
• Attendant
• Attendant
0x0E76
Sensors in coin input funnel
defective (no signal)
Critical
Hardware replacement, contact
service
Service
0x0E78
No manufacturing data
stored in coin input funnel
Critical
Hardware replacement, contact
service
Service
0x0E7A
PDI and flash not protected
Critical
Hardware replacement, contact
service
Service
0x0E80
Coin(s) seem(s) to be
stuck in input tray for over
2 minutes after successful
power-on
Critical
• Remove coin(s) or foreign objects
from input funnel and power cycle
the CLS
• If necessary, clean coin input
funnel
(cf. Chap. "8.4.1 Cleaning the
housing, coin input funnel and return
tray", p. 36)
• Attendant
• Attendant
Error code Description/Cause
Category
Remedy/hints
By whom
0x0EDD
Coin input funnel is in boot
loader mode
Critical
Firmware failure, contact service
Service
0x1165
Main PCB communication
failure. CLS control unit was
unable to establish commu-
nication with the Main PCB
Critical
Hardware replacement, contact
service
Service
0x11D4
Main PCB FW upgrade:
invalid command (IAP#1).
FW file is corrupt
Attention
FW file failure, contact service
Service
0x11D5
Main PCB FW upgrade:
source address is not on a
word boundary (IAP#2). FW
file is corrupt
Attention
FW file failure, contact service
Service
0x11D6
Main PCB FW upgrade:
destination address is not on
a correct boundary (IAP#3).
FW file is corrupt
Attention
FW file failure, contact service
Service
0x11D7
Main PCB FW upgrade: byte
count is not multiple of 4
or is not a permitted value
(IAP#6). FW file is corrupt
Attention
FW file failure, contact service
Service
0x11D8
Main PCB FW upgrade:
sector number is invalid
(IAP#7). FW file is corrupt
Attention
FW file failure, contact service
Service
0x11D9
Main PCB FW upgrade: sec-
tor is not blank (IAP#8). FW
file is corrupt
Attention
FW file failure, contact service
Service
0x11DA
Main PCB FW upgrade: sec-
tor is not prepared (IAP#9).
FW file is corrupt
Attention
FW file failure, contact service
Service
0x11DB
Main PCB FW upgrade:
source and destination data
is not same (IAP#10). FW
file is corrupt
Attention
FW file failure, contact service
Service
0x11DC
Main PCB FW upgrade: flash
programming hardware
interface is busy (IAP#11)
Attention
Reset CLS, contact service
Service
0x11DD
Main PCB FW upgrade: Main
PCB is in boot loader mode
Critical
FW file failure, contact service
Service
0x8000
Power-on or ccTalk reset
command successful. CLS in
ready state
Info