3
312020000
INSTALLATION
This section describes receiving, unpacking,
selecting location, and installation of the Unit.
RECEIVING
Each Unit is completely tested under operating
conditions and thoroughly inspected before
shipment. At time of shipment, the carrier accepts
the Unit and any claim for damage in transit must be
made with the carrier. Upon receiving Unit from the
delivering carrier, carefully inspect the carton for
visible indication of damage. Any damage or
irregularities should be noted at time of delivery (or
not later than 15 days from date of delivery) and
immediately reported to the delivering carrier.
Request a written inspection report from the Claims
Inspector to substantiate claim. File claim with the
delivering carrier, not with IMI Cornelius Inc.
UNPACKING AND INSPECTION
Unpack Unit as follows:
1. Carefully remove packaging material.
2. Retain Service Manual and loose-shipped parts.
3. Inspect all parts of the Unit for evidence of
damage. If such evidence is found, file a claim
against the carrier.
4. Remove loose-shipped parts from poly bags
and check their identity and quantity against
Table 2.
Table 2. Loose-Shipped Parts
Item
No.
Part No.
Name
Qty
41-6401
Unit
Qty
41-6402
Unit
1
397180-039
Cup Rest
1
2
397179-039
Drip Tray
1
3
178025-100
Tapered Plastic
Gasket
2
2
4
770716-020
Adapter Fitting,
7/16-20 Female by
5/8-18 Male
1
1
5
312071-000
Decal Kit
1
1
6
312020–000
Service Manual
1
1
7
312971-000
Mounting Screws
2
2
8
300098-000
Hole Plugs
2
2
9
151707
Screw, Thd Rolling,
8–32 By 3/8 in. long
2
2
IDENTIFICATION OF LOOSE-SHIPPED
PARTS
1. CUP REST (item 1) fits inside DRIP TRAY (item
2).
2. DRIP TRAY (item 2) supports cup rest and
receives product spillage.
3. TAPERED PLASTIC GASKETS (item 3) seal
water and concentrate connections at rear of
Unit.
4. ADAPTER FITTING (item 4) connects 3/8 in.
O.D. plain water source line to the Unit.
5. DECAL KIT (item 5). Decals for product
identification on the Unit and front of dispensing
valve – Instructions for applying decals included.
6. SERVICE MANUAL (item 6). A guide to
installation, operation, and maintenance of the
Unit.
7. MOUNTING SCREWS (item 7) for mounting
Unit Base to counter, if desired.
8. HOLE PLUGS (item 8) to close inlet openings in
back of Unit if inlet lines are routed down
through counter top.
9. SCREW (item 9) to secure cover on top of the
Unit.
SELECTING LOCATION
This Unit may be island-mounted or installed on a
front or rear countertop provided that the following
requirements are satisfied. Unit may be fastened to
countertop using screws through Unit Base.
1. Locate Unit near a source of cold (100
°
F max)
plain water having a pressure of 40 to 125 psig.
2. Locate Unit to minimize length of concentrate
line.
To comply with National Sanitation Foundation (NSF)
requirements within the United States, Unit base
must be sealed to countertop when screws are used
to fasten Unit Base to countertop. Proceed as follows
to seal base to countertop.
1. Tilt up to expose bottom of base.
2. Liberally apply silastic sealant (such as Dow
Corning RTV 731 or equivalent) on base bottom
edges.
Note: Do not move Unit after positioning or seal