The Tea Urn Manual 312020-000 was revised. Removed all information in regard to a syrup tank 

hookup and made it only a bag-in-box hookup. This revised manual was never released on a PCN. Talked

to George Murphy about this (08/11/94) and he said not to be in a hurry to release the revised manual as they

have a rather large stock of old manuals in stock showing the syrup tank hookup along with the bag-in-box

hookup which he said is no big deal.

Summary of Contents for TEA URN

Page 1: ...ectly connected to a potable water supply shall be sized installed and maintained according to Federal State and Local laws Printed in U S A 94 IMI CORNELIUS INC 1993 94 IMI CORNELIUS INC One Corneliu...

Page 2: ...OX CONCENTRATE SYSTEMS 9 CLEANING THE NITROGEN GAS CHECK VALVE 9 PAGE TROUBLESHOOTING 13 WATER TO CONCENTRATE RATIO OF DIS PENSED PRODUCT TOO LOW OR TOO HIGH 13 ADJUSTMENT OF DISPENSING VALVE CON CENT...

Page 3: ...approximate Shipping 11 pounds Dry Weight 8 pounds Dispensing Rate approx 1 1 2 ounces sec Ambient Operating Temperature 40_F to 100_F Operating Pressures Water Inlet Supply Line 40 to 125 psig FIGUR...

Page 4: ...DIOXIDE CO2 GAS CYLINDER ADJUSTABLE CONCENTRATE FLOW REGULATOR ADJUSTABLE WATER FLOW REGULATOR SHUTOFF VALVE LINE LEGEND WATER CONCENTRATE GAS DISPENSER BAG IN BOX CONCENTRATE CONTAINER CONCENTRATE P...

Page 5: ...Hole Plugs 2 2 9 151707 Screw Thd Rolling 8 32 By 3 8 in long 2 2 IDENTIFICATION OF LOOSE SHIPPED PARTS 1 CUP REST item 1 fits inside DRIP TRAY item 2 2 DRIP TRAY item 2 supports cup rest and receives...

Page 6: ...TS item 3 2 Connect other end of concentrate source line connected to the Unit to outlet fitting on bag in box concentrate pump 3 Connect concentrate source line from bag in box location to inlet fitt...

Page 7: ...To syrup Ratio of dispensed product should be checked periodically and adjusted if necessary Refer to SERVICE AND MAINTENANCE section of this manual for adjustment procedure ADJUSTING PRIMARY CO2 REG...

Page 8: ...ECK VALVES The CO2 gas check valve must be inspected and serviced as instructed at least once a year under normal conditions and after any CO2 system servicing or disruption Servicing of CO2 gas check...

Page 9: ...the amount of water was too much turn dispensing valve water flow regulator adjusting screw Figure 3 counterclockwise a quarter of a turn at a time Repeat dispensed water measurement after each adjust...

Page 10: ...leaning instructions is to remove only external residue from the valve and it s baffle and nozzle 1 Remove acorn nut securing dispensing valve cover then remove cover 2 Remove nozzle and baffle assemb...

Page 11: ...n the entire CO2 and soft drink system If a CO2 gas leak is suspected particularly in a small area immediately ventilate the contaminated area before attempting to repair the leak Personnel exposed to...

Page 12: ...G CO2 SYSTEM CO2 GAS CHECK VALVES see Figures 2 and 4 The primary CO2 regulator CO2 gas check valve must be inspected and serviced at least once a year under normal conditions and after any servicing...

Page 13: ...mp A Adjust primary CO2 regulator or check CO2 supply and replenish as instructed B No concentrate supply B Replenish concentrate supply as instructed C Quick disconnect not secure on bag in box conta...

Page 14: ...d E Adjust Water to Concentrate Ratio of dispensed product as instructed F No CO2 gas supply F Replenish CO2 gas supply as instructed G Dispensing valve concentrate flow regulator bag in box quick dis...

Page 15: ...TER D WARWICKSHIRE B49 6 EU ENGLAND D 44 789 763 101 D FAX 44 789 763 644 FRANCE D 71 ROUTE DE ST DENIS D F 95170 DEUIL LA BARRE D PARIS FRANCE D 33 1 34 28 6200 D FAX 33 1 34 28 6201 GERMANY D CARL L...

Page 16: ...ag in box hookup This revised manual was never released on a PCN Talked to George Murphy about this 08 11 94 and he said not to be in a hurry to release the revised manual as they have a rather large...